Waste container latch removal
See
"Waste container latch" on page 7-18
1.
Remove the paper size sensing assembly. See
2.
Use a flatblade screwdriver to release the waste container latch from the paper size sensing assembly.
Web oiler fuser kit installation
See
"Fuser web oiler upgrade kit and replacements" on page 1-4
1.
Enter CE Diagnostic mode.
2.
Select Printer Setup.
3.
Select Configuration ID.
4.
Increase the last two digits each by four.
Configuration ID
=123456*
The left digit blinks, indicating it is the first digit to be changed. Press Select to accept the current value and
skip to the next digit. Change the two digits on the right to increase each of their values by four. For
example, in this case, change 123456 to 12349A. To change the value of a digit, press Menu until the
desired value is displayed and press Select. When the last (rightmost digit) is changed and Select is
pressed, the new value is set. The printer automatically begins POR.
5.
Turn the printer off.
6.
Open the fuser access cover.
for the part number.
"Paper size sensing assembly removal" on page
for the part number.
5060-00x
4-48.
4-85