xStack
DGS-3120 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
Restrictions
Only Administrator, and Operator level users can issue this command.
Example
To configure the port 21's temperature threshold:
DGS-3120-24TC:admin#config ddm ports 1:21 temperature_threshold high_alarm
84.9555 low_alarm -10 high_warning 70 low_warning 2.25251
Command: config ddm ports 1:21 temperature_threshold high_alarm 84.9555
low_alarm -10 high_warning 70 low_warning 2.25251
Success.
DGS-3120-24TC:admin#
To configure the port 21's voltage threshold:
DGS-3120-24TC:admin#config ddm ports 1:21 voltage_threshold high_alarm 4.25
low_alarm 2.5 high_warning 3.5 low_warning 3
Command: config ddm ports 1:21 voltage_threshold high_alarm 4.25 low_alarm 2.5
high_warning 3.5 low_warning 3
Success.
DGS-3120-24TC:admin#
To configure the port 21's bias current threshold:
DGS-3120-24TC:admin#config ddm ports 1:21 bias_current_threshold high_alarm
7.25 low_alarm 0.004 high_warning 0.5 low_warning 0.008
Command: config ddm ports 1:21 bias_current_threshold high_alarm 7.25 low_alarm
0.004 high_warning 0.5 low_warning 0.008
Success.
DGS-3120-24TC:admin#
To configure the port 21's transmit power threshold:
DGS-3120-24TC:admin#config ddm ports 1:21 tx_power_threshold high_alarm 0.625
low_alarm 0.006 high_warning 0.55 low_warning 0.008
Command: config ddm ports 1:21 tx_power_threshold high_alarm 0.625 low_alarm
0.006 high_warning 0.55 low_warning 0.008
Success.
DGS-3120-24TC:admin#
To configure the port 21's receive power threshold: