DEVICENET COMMUNICATION CARD
NET LED
LED status
Green light on
Red light on
Red light flashes
Orange light flashes
DEVICENET COMMUNICATION CARD
Features
1. Based on the high-speed communication interface of Honeywell HSSP protocol, able to conduct immediate control to the
VFD.
2. Supports Group 2 only connection and polling I/O data exchange.
3. For I/O mapping, supports Max. 32 words of input and 32 words of output.
4. Supports EDS file configuration in DeviceNet configuration software.
5. Supports all baud rates on DeviceNet bus: 125kbps, 250kbps, 500kbps and extendable serial transmission speed mode.
6. Node address and serial transmission speed can be set up on VFD.
7. Power supplied from the VFD.
Product introduction
63-4528—04
Indication
Normal status
PROFIBUS DP COMMUNICATION CARD
is not connected to PROFIBUS DP bus.
Invalid PROFIBUS communication
address
PROFIBUS DP COMMUNICATION CARD
fails to communication with VFD.
6
1
2
3
4
5
7
Action
No action required
Connect PROFIBUS DP COMMUNICATION CARD to
PROFIBUS DP bus.
Set the PROFIBUS address of PROFIBUS DP
COMMUNICATION CARD between 1 ~ 125 (decimal)
Switch off the power and check whether PROFIBUS DP
COMMUNICATION CARD is correctly and normally
connected to VFD.
8
M33580
78
1. NS indicator
2. MS indicator
3. POWER indicator
4. Positioning hole
5. DeviceNet connection port
6. Screw fixing hole
7. Fool-proof groove
8. VFD connection port