CHAPTER 12: DESCRIPTION OF PARAMETER SETTINGS
Table of Functions
[For Normally Open (N.O.) Contacts. ON means contact is CLOSED; OFF means contact is OPEN.]
Settings
Functions
0
No Function
Multi-step speed command 1 /
1
Multi-step position command 1
Multi-step speed command 2 /
2
Multi-step position command 2
Multi-step speed command 3 /
3
Multi-step position command 3
Multi-step speed command 4 /
4
Multi-step position command 4
5
Reset
6
JOG Command
Acceleration / Deceleration
7
Speed Inhibit
st
nd
The 1
, 2
acceleration or
8
deceleration time selection
rd
th
The 3
, 4
acceleration or
9
deceleration time selection
63-4528—04
Table 1. Table of Functions
15-step speeds or 15-step positions could be conducted through the digital status of
the 4 terminals. It will be 16 in total if the master speed is included. (Refer to
Parameter set 4)
After the error of the drive is eliminated, use this terminal to reset the drive.
Before executing this function, wait for the drive stop completely. While the drive is
running, the operating direction can be modified and STOP key on the keypad is still
valid. Once the external terminal receives OFF command, the motor will stop by the
JOG deceleration time. Refer to Pr.01-20~01-22 for details.
FREQUENCY
01-22
JOG FREQUENCY
01-07
MIN. OUTPUT
FREQ. OF MOTOR 1
MI X-GND
When this function is enabled, the acceleration and deceleration are stopped right
away. After this function is disabled, the VFD re-starts to accel./decel. from the
inhibiting point.
FREQUENCY
SETTING
FREQUENCY
MI X-GND
OPERATION
COMMAND
The acceleration/deceleration time of the drive can be selected from this function or
the digital status of the terminals; there are 4 acceleration/deceleration speeds in
total for selection.
148
Descriptions
JOG ACCEL. TIME
JOG DECEL. TIME
01-20
ON
ACCEL.
DECEL.
INHIBIT
INHIBIT
AREA
AREA
ACCEL.
INHIBIT
AREA
ACTUAL OPERATION FREQUENCY
ON
ON
ON
ON
TIME
01-21
OFF
M33637
DECEL.
INHIBIT
AREA
TIME
ON
OFF
M33638