85~100: Reserved
101: CGdE CANopen software disconnect1
102: CHbE CANopen software disconnect2
103: CSYE CANopen synchronous error
104: CbFE CANopen hardware disconnect
105: CIdE CANopen index setting error
106: CAdE CANopen slave station number setting error
107: CFrE CANopen index setting exceed limit
06 - 26
PTC (Positive Temperature Coefficient) Detection Selection
Settings
• This is the operating mode of a drive after Pr.06-26 is set to define PTC detection.
06 - 27
PTC Level
Settings
• It needs to set AVI1/ACI/AVI2 analog input function Pr.03-00~03-02 to 6 (P.T.C. thermistor input value).
• It is used to set the PTC level, and the corresponding value for 100% is max. analog input value.
06 - 28
Frequency Command for Malfunction
Settings
• When malfunction occurs, use can check the frequency command. If it happens again, it will overwrite the previous record.
06 - 29
Output Frequency at Malfunction
Settings
• When malfunction occurs, use can check the current frequency command. If it happens again, it will overwrite the previous
record.
06 - 30
Output Voltage at Malfunction
Settings
• When malfunction occurs, user can check current output voltage. If it happens again, it will overwrite the previous record.
06 - 31
DC Voltage at Malfunction
Settings
0: Warn and keep operating
1: Warn and ramp to stop
2: Warn and coast to stop
3: No warning
0.0~100.0%
0.00~655.35Hz
0.00~655.35Hz
0.0~6553.5V
0.0~6553.5V
CHAPTER 12: DESCRIPTION OF PARAMETER SETTINGS
185
Factory Setting: 0
Factory Setting: 50.0
Factory Setting: Read Only
Factory Setting: Read Only
Factory Setting: Red Only
Factory Setting: Read Only