00 - 09
Display Advanced Parameters
Settings
00 - 10
Velocity Control Mode
Settings
• This parameter determines the control method of the VFD:?
— 0: V/F control: user can design proportion of V/f as required and can control multiple motors simultaneously.
— 2: Sensorless vector control: get the optimal control by the auto-tuning of motor parameters.
• When setting Pr.00-10 to 0, the V/F control diagram is shown as follows.
DECODE FLOW CHART
00-08
PASSWORD SET
00-07
PASSWORD INPUT
YES
PR.00-08
0
NO
RE-APPLY POWER
(PASSWORD IS STILL VALID)
Bit 0: Group 0
Bit 1: Group 1
Bit 2: Group 2
Bit 3: Group 3
Bit 4: Group 4
Bit 5: Group 5
Bit 6: Group 6
Bit 7: Group 7
Bit 8: Group 8
Bit 9: Group 9
(Bin Setting and Display for LCD Keypad)
0: V/F (V/F control)
2: SVC (Sensorless Vector Control)
CHAPTER 12: DESCRIPTION OF PARAMETER SETTINGS
SHUT DOWN THE DRIVE
AND RE-APPLY POWER
M33606
127
Factory Setting: 0
Factory Setting: 0