CHAPTER 11 TROUBLESHOOTING
Cause
Step
Environment
Main thermistor
(TH1)
DC controller
PCB

2. E001

Cause
Step
Thermistor
(TH1/TH2)
DC controller
PCB
AC driver
DC controller
PCB
11-84
COPYRIGHT © 1997 CANON INC.
Checks
6
Does the problem occur only
when the machine is turned on for
the first time in the morning?
7
Replace the thermistor. Is the
problem corrected?
Checks
1
Execute 'ERROR' in service mode
(
), and open the front door
4
and the delivery assembly to cool
the fixing roller. Is 'E001' indicated
immediately after power-on when
the power switch is turned on?
2
Turn off the power switch, and
slide out the fixing feeding assem-
bly. Disconnect the relay connec-
tor J2757 from inside the fixing
unit, and set the meter to the 1K
range. Connect the probe to the
terminal of the harness on the
thermistor side. Is the reading
about 0
at this time? (After the
check, be sure to connect J2757.)
3
Replace the AC driver. Is the
problem corrected?
CANON NP6560/NP6360/NP6260 REV. 0 NOV. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
YES/NO
Action
YES
•Advise the user that the
site is out of
specification.
•Advise the user not to
turn on the machine
until the room is warm
enough.
YES
End.
NO
Replace the DC
controller PCB.
YES/NO
Action
NO
Go to step 3.
YES
Replace the thermistor.
NO
Replace the DC
controller PCB.
YES
End.
NO
Check the wiring from
the AC drive to the DC
controller; if normal,
replace the DC controller
PCB.