CHAPTER 9 INSTALLATION
B. Installing to the Copier
Keep the following in mind when installing the Copy Data Controller-A1 to the copier:
1. Observe the laws and regulations of the country.
2. Make sure that the copier has been properly installed before starting the work.
3. Make sure that the copier's power plug is disconnected during the work.
4. Identify the type of screw (length, diameter), and be sure to use the correct screws.
5. Prepare settings data in advance on a computer at the service station. (This applies
only when remote control is desired.)
1) Remove the four screws, and remove the face plate from the copier's rear cover.
2) Remove the relay postheader from the cable, and connect it directly to the connector
on the copier's DC controller PCB.
9-44
COPYRIGHT © 1997 CANON INC.
Screws
Figure 9-507
Connector for
Copy Data Controller-A1
(8P)
Figure 9-508
CANON NP6560/NP6360/NP6260 REV. 0 NOV. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)