3. Separation Corona Current (DC component)
For the output of the separation corona current (DC component), DC current is var-
ied to suit the voltage level (3 to 11 V) of HVSCT.

4. Pre-Transfer Corona Current (DC component)

The level of the pre-transfer corona current (DC component) is varied according to
the voltage level of DCPC.
COPYRIGHT © 1997 CANON INC.

Separation corona current

(µA)
-500
100
3
Voltage level (V) of HVSCT
Figure 4-116
Pre-transfer corona current
(µA)
-330
0
3
Voltage level (V) of DCPC
Figure 4-117
CANON NP6560/NP6360/NP6260 REV. 0 NOV. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)