Step
11
Insert the drum rotating tool into the
cut-in of the drum shaft. While holding
the rotating tool so as to prevent the
drum from rotating counterclockwise,
remove the drum fixing screw and the
drum fixing (cut-in member).
Caution:
1. If you let the drum to rotate
counterclockwise, the cleaning
blade will not be in contact with
the drum correctly, causing
cleaning faults. To prevent such
faults, be sure to hold the drum in
place before removing the drum
fixing screw.
2. Do not expose the photosensitive
drum to light for longer than 30
min.
3. Do
not
photosensitive drum to direct
rays of the sun.
4. Whenever
photosensitive drum or the
process
machine, be sure to cover it with
six or more sheets of copy paper
to protect it against light.
12
Slide out the fixing/feeding assembly
while paying attention to the hopper.
Place the drum protection sheet that
comes with the machine to protect
the rubber roller of the registration
roller assembly and the drum.
13
Slide out the process unit to the front,
and insert the drum rotating tool that
comes with the machine into the
front of the drum shaft; while rotating
the drum clockwise, check to make
sure that the drum is free of damage.
COPYRIGHT © 1997 CANON INC.
Work
ever
expose
the
placing
the
unit
outside
the
CANON NP6560/NP6360/NP6260 REV. 0 NOV. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 9 INSTALLATION
Remarks
Drum shaft
Cut-in
Rotating tool
9-13