Installation
Procedure
1.
Run the DIW
enough slack for dressing the wire.
2.
Attach a Unicon plug to the CU end of the DIW cord by using
the 4-pair plug presser.
3.
Plug the DIW cord into the CU and connect the other end to
the station jack (see "Terminating Cable at a Station Outlet" in
this chapter).
4.
Repeat steps 1 to 3 for each station line.
Dress the wires properly by using cable ties. Fasten wire runs
5.
vertically to the left or right of the CU. The final horizontal wire
run to the CU must be fastened within 12 inches of the CU.
Allow sufficient slack to reach any port on the CU.
6.
Label the CU module jacks, station jacks, and DIW cords
properly (see "Label the System Wiring" in this chapter).
Over 24 Stations
For systems with more than 24 stations, the two recommended
methods are Interconnect Wiring and SYSTIMAX.
Interconnect Wiring
Interconnect Wiring is required when the system has more than
24 stations and SYSTIMAX has not been ordered. The
Interconnect Wiring module provides the hardware to
interconnect up to 12 stations with 110-type wiring.
For Interconnect Wiring, you must build a jack field between the
CU and the stations by using 110AB1-100JP12 termination
blocks with modular jacks and 110A1 wire troughs.
3-88 System Wiring
cord from the CU to the station and cut it. Allow