Installation
Table 3-33 CO Network Interface Codes
Line/
Trunk Type
LS CO line
GS CO trunk
DID
OPS
Tie trunk
DS1
* The preferred network interface is the RJ48X. With the RJ48X interface, if no
connection is provided by the customer's equipment, the T1 facility's receive
pair is looped back to the transmit pair. This simplifies troubleshooting the T1
facility.
In most installations, the network interface is connected through
a cross-connect field to the CU. However, for systems with fewer
than 24 stations, the line/trunk wires can be directly connected to
the CU.
Note: When constructing wiring fields between the network
interface and the CU, you must order hardware as individual
parts. Do not use Interconnect Wiring or SYSTIMAX kits.
3-80 System Wiring
Federal Interface
Code for Facility
02LS2
02GS2
02RV2-T
0L13C
TL31M
04DU9-B
04DU9-C
Network
Interface
RJ11C, RJ14C
RJ21
RJ11C, RJ14C,
RJ21
RJ11C, RJ14C,
RJ21
RJ11C
RJ2GX
RJ48C/X*