Input Tray Tests; Feed Test; Sensor Test - Lexmark C752 Service Manual

Service manual
Hide thumbs Also See for C752:
Table of Contents

Advertisement

Input Tray Tests

Feed Test

This test lets you observe the paper path as media is feeding through the printer. The upper front door, used to
access the print cartridge, cannot be opened during the feed test. To observe the paper path, you must open the
lower front door, used to access the paper jams on the vacuum transport belt. Blank pages feed during the test.
Note: This test can run using any of the paper or envelope sizes supported by the printer. The pages are placed
in the default output bin, however, the Feed Test menu lets you select the input source.
To run the Input Tray Feed Test:
1.
Select Feed Test from the menu.
2.
Select the input source from the sources displayed on the Feed Test menu. All installed sources are
displayed.
3.
Select either Single (feeds one sheet of media from the selected source) or Continuous (continues to
feed from the selected source until Return or Stop is pressed).
4.
Press Return or Stop to exit test.

Sensor Test

This test can be used for either 500-sheet trays or 2000-sheet trays.
500-sheet trays
Use this test to determine if the input tray sensors for a 500-sheet tray are working correctly.
To run the Sensor Test for 500-sheet trays:
1.
Select the Sensor Test from the Input Tray Test menu.
Sensor L1=Input Tray level/empty Sensor 1
Sensor L2=Input Tray level/empty Sensor 2
Sensor P=Input Tray Pass Thru Sensor
2.
Once this message appears, you can manually actuate each sensor. The tray empty sensor can be
actuated by hand, however a sheet of paper can be used to cover the pass thru sensor. When the sensor
is closed, CL displays, when the sensor is open, OP appears.
3.
Press Return or Stop to exit the test.
Tray sensors are supported by the following sources:
Source
Tray 1
Tray 2
Tray 3
Tray 4
Multipurpose Feeder
1
L1
Yes
1
Yes
1
Yes
1
Yes
Yes
2000-sheet trays may be in this position. See
Pass thru
L2
sensor
Yes
Not present
Yes
Yes
Yes
Yes
Yes
Yes
Not present
Not present
"For 2000-sheet
trays".
5060-2XX
3-25