130 Error Code - Lexmark C752 Service Manual

Service manual
Hide thumbs Also See for C752:
Table of Contents

Advertisement

5060-2XX

130 error code

Hot roll did not reach the correct standby temperature
This error displays when the fuser hot roll does not reach the correct standby temperature.
Step
Action and questions
1
Measure the voltage on connector J33-11 on the
system board.
The voltage measures approximately 0.13 V dc to
0.64 V dc as the hot roll lamp turns off and on.
Is the voltage correct?
2
Remove the fuser from the printer. Check continuity of
the hot roll lamp by measuring between pins 1 and 2
on the AC fuser connector on the fuser assembly.
Is there continuity?
3
Check to make sure that the hot roll lamp is installed
correctly.
Is the hot roll lamp installed correctly?
4
Reinstall the fuser assembly. Watch to see if the lamps
turn on and off as the lamp heat up.
Do the lamps turn on?
5
Turn the printer on and allow it to reach a Ready
prompt.
Note: The printer may not complete POR and
continues to display the error code.
Remove the fuser assembly from the printer. Measure
the voltage on connector J33-6 on the system board.
The voltage should measure approximately +3.3 V dc.
Is the voltage correct?
6
Measure the voltage on the fuser DC control connector
on the LVPS. Measure the voltage on pin 6 of the
connector.
Does the voltage measure approximately +3.3 V dc?
2-50
Service Manual
Yes
No
Replace the
Go to step 2
"Fuser
assembly" on
page
4-32.
Go to step 4
Go to step 3
Go to step 4
Install the lamp
correctly. If this
does not fix the
problem, replace
the
"Fuser
assembly" on
page
Go to step 5
Replace the
"LVPS
assembly" on
page
Go to step 6
Replace the
"System board"
on page
Replace the
Replace the
"Fuser
"LVPS
assembly" on
assembly" on
page
4-32.
page
4-32.
4-42.
4-67.
4-42.