Lexmark C752 Service Manual page 133

Service manual
Hide thumbs Also See for C752:
Table of Contents

Advertisement

Ready bin x full message - may be able to clear message and will feed paper into bin
selected.
Note: This sensor is normally in a open position with the flag out of the sensor slot.
Step
Action and questions
1
Bin x sensor (bin x=Sensor 1 through 5) - Make sure
the sensor is seated correctly in the side of tray x.
Is the sensor seated correctly?
2
Bin x sensor cable - Make sure that bin x sensor cable
is connected to the sensor and to the control board.
Is the sensor cable connected correctly?
3
Bin x sensor flag - Check the bin x sensor flag for
binding and proper operation.
Are there any problems with the sensor flag?
4
Bin x sensor cable - Check the continuity of the sensor
cable.
Is there continuity?
Bin x full - no message that bin x is full message
Step
Action and questions
1
Bin x sensor (bin x=sensor 1 through 5) - Make sure
the sensor is seated correctly in the side of tray x.
Is the sensor seated correctly?
2
Bin x sensor cable - Make sure that bin x sensor cable
is connected to the sensor and to the control board.
Is the sensor cable connected correctly?
3
Bin x sensor flag - check the bin x sensor flag for
binding and proper operation.
Are there any problems with the sensor flag?
4
Bin x sensor cable - Check the continuity of the sensor
cable.
Is there continuity?
Ready - bin x full displays and paper feeds into bin x
Step
Action and questions
1
Bin x sensor flag - Make sure the bin x sensor flag is
not in the up position and is operating correctly.
Is the sensor flag operating correctly?
Yes
No
Go to step 2
Install the sensor
correctly
Go to step 3
Install the sensor
cable correctly
Repair or replace
Go to step 4
the sensor flag
Replace the bin x
Replace the bin x
sensor
Cable
Yes
No
Go to step 2
Install the sensor
correctly
Go to step 3
Install the sensor
cable correctly
Repair or replace
Go to step 4
the sensor flag
Replace the bin x
Replace the bin x
sensor
cable
Yes
No
Replace the bin x
Repair or replace
sensor. If this
as necessary
does not fix the
problem replace
the control board.
Diagnostic information
5060-2XX
2-99

Hide quick links:

Advertisement

Table of Contents
loading