Advertisement

5060-2XX
HCIT inoperative
Before proceeding with this service check make sure the 2000-sheet tray option is properly connected to AC
power.
If a finisher is installed:
The AC jumper should go from the HCIT to the finisher. The finisher AC power cord should attach to the
AC voltage source. The base printer power cord should plug into the AC output connector on the HCIT.
If a finisher is not installed:
The printer power cord plugs into the HCIT AC outlet and the power cord from the HCIT plugs into the AC
voltage source.
Note: Make sure the electrical outlet is working properly and all power cords are plugged in correctly. Make sure
the slide switch on the LVPS is toward the right.
The system board status LED can be observed by removing the rear cover. The LED is mounted on the HCIT
system board.
Step
Action and questions
1
Does the printer power up and work normally when
plugged into the AC outlet on the HCIT?
2
Check the system board LED. Is it is on solid or
blinking?
• On solid means that the HCIT has detected the
front door or side door open.
• Blinking means that the system is operating.
Is the LED on solid or blinking?
3
Measure the voltage at TP3 (+5 V dc test point) on the
HCIT system board. The voltage should measure
approximately +5 V dc.
Is the voltage correct?
4
Measure the voltage at CN2 pin 2 on the HCIT system
board. The voltage should measure approximately +5
V dc.
Is the voltage correct?
5
Check the AC line voltage at the input to the LVPS.
Is the voltage correct?
6
Check the AC cable from the HCIT AC inlet to the
LVPS.
Are the cables good?
2-120
Service Manual
Yes
No
Go to step 2
Go to step 5
If the LED is on
Go to step 3
solid, check the
front and side
doors. If the LED
is blinking,
replace the HCIT
system board
Replace the
Go to step 4
HCIT system
board
Replace the
Go to step 5
HCIT system
board
Replace the
Go to step 6
HCIT LVPS
Determine where
Replace the
the AC line
cables
voltage is being
lost to the HCIT.
Repair as
necessary.