128 error code

Fuser hot roll is under temperature during standby
Step
Action and questions
1
Turn the printer on and allow it to reach a Ready
prompt.
Note: The printer may not complete POR and continue
to display the 128 Error message.
Remove the fuser assembly from the printer. Measure
the voltage on connector J33-6 on the system board.
The voltage should measure approximately 3.3 V dc.
Is the voltage correct?
2
Measure the voltage on the fuser DC control connector
on the LVPS. Measure the voltage on pin 6 of the
connector.
Does the voltage measure approximately +3.3 V dc.
129 error code
Fuser backup roll is under temperature during standby.
Step
Action and questions
1
Turn the printer on and allow it to reach a Ready
prompt.
Note: The printer may not complete POR and
continues to display the 129 Error message.
Remove the fuser assembly from the printer. Measure
the voltage on connector J33-7 on the system board.
The voltage should measure approximately +3.3 V dc.
Is the voltage correct?
2
Measure the voltage on the fuser DC control connector
on the LVPS. Measure the voltage on pin 7 of the
connector.
Does the voltage measure approximately +3.3 V dc.
Yes
No
Go to step 2
Replace the
"System board"
on page
Replace
Replace the
the"Fuser
"LVPS
assembly" on
assembly" on
page
4-32.
page
Yes
No
Go to step 2
Replace the
"System board"
on page
Replace
Replace the
the"Fuser
"LVPS
assembly" on
assembly" on
page
4-32.
page
Diagnostic information
5060-2XX
4-67.
4-42.
4-67.
4-42.