Firmware Checkpoints - IBM RS/6000 7043 43P Series Service Manual

Hide thumbs Also See for RS/6000 7043 43P Series:
Table of Contents

Advertisement

Firmware Checkpoints

The following Fxx code checkpoints are displayed on the operator panel during
system startup, and can be used for diagnostic purposes.
If you replace FRUs and the problem is still not corrected, go to MAP 0030 in the
Diagnostics Information for Multiple Bus Systems unless otherwise indicated in the
tables.
Table 3-4 (Page 1 of 5). Firmware Checkpoints.
Checkpoint
Description
F01
Performing system memory test
(May take several minutes if large
amount of memory installed.)
F05
Transfer control to Operating
System (normal boot).
F22
No memory detected (system
lockup) Note: The disk drive light is
on continuously.
F2C
Processor card mismatch (Model
240)
F4D
Loading boot image
F4F
NVRAM initialization
F51
Probing primary PCI bus
F52
Probing for adapter FCODE,
evaluate if present
3-14
7043 43P Series Service Guide
Action/
Possible Failing FRU
1. Memory modules.
2. System board
See "Fxx Code Boot Problems" on
page 3-18.
1. Memory modules
2. System board. (See 3-1.)
If more than one processor card is
installed in the Model 240, both
processor cards must be of the
same speed and type.
See "Fxx Code Boot Problems" on
page 3-18.
Go to "MAP 1540: Minimum
Configuration" on page 2-21.
1. PCI Adapters
2. Riser card
3. System board.
If a network adapter or system
board is replaced, see 3-1.
1. PCI Adapters
2. Riser card
3. System board.
If a network adapter or system
board is replaced, see 3-1.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents