Usb-Inactivity-Timeout - Cisco Catalyst 3560X-24P Command Reference Manual

Cisco ios release 12.2(55)se
Hide thumbs Also See for Catalyst 3560X-24P:
Table of Contents

Advertisement

usb-inactivity-timeout

usb-inactivity-timeout
To configure an inactivity timeout on the USB console, use the usb-inactivity-timeout command in
console line configuration mode. To remove the inactivity timeout use the no form of this command.
Syntax Description
minutes
Defaults
Inactivity timeout is not configured.
Command Modes
Line configuration
Command History
Release
12.2(53)SE2
Usage Guidelines
The switch has a configurable timeout inactivity that activates the RJ-45 console if the USB console has
been activated but no input activity has occurred on the USB console for a specified time period. When
the USB console is deactivated due to an inactivity timeout, you can restore its operation by
disconnecting and reconnecting the USB cable.
Examples
This example shows how to configure the inactivity timeout:
Switch# configure terminal
Switch(config)# line console 0
Switch(config-line)# usb-inactivity-timeout 60
If there is no input on the USB console for 60 minutes, the console changes to RJ-45, and a system
message log appears showing the inactivity timeout.
Related Commands
Command
no media-type rj45
Catalyst 3750-X and 3560-X Switch Command Reference
2-922
usb-inactivity-timeout minutes
no usb-inactivity-timeout minutes
Time, in minutes, before the console port changes to the RJ-45 port due to inactivity
on the USB console. The range is 1 to 240. The default is no timeout.
Modification
This command was introduced.
Description
Resets the console port as the USB port if it has been manually set to the
RJ-45 port.
Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands