Molded-Case Circuit Breaker And Fuse Capacity - YASKAWA SGLFW User Manual

Linear σ series servomotors
Hide thumbs Also See for SGLFW:
Table of Contents

Advertisement

2.6.2 Molded-case Circuit Breaker and Fuse Capacity

SERVOPACK
Main
Model
Circuit
Power
Supply
Capacity
SGDH-
(kW)
0.05
A5AE
Single-
0.10
01AE
phase
0.20
02AE
200 V
0.40
04AE
0.45
05AE
0.75
08AE
1.0
10AE
Three-
1.5
15AE
phase
2.0
20AE
200 V
3.0
30AE
5.0
50AE
7.5
75AE
0.45
05DE
1.0
10DE
1.5
15DE
Three-
2.0
20DE
phase
400 V
3.0
30DE
5.0
50DE
7.5
75DE
* 1. Nominal value at the rated load. The specified derating is required to select an appropriate
fuse capacity.
* 2. Cutoff characteristics (25
* 3. A preventive circuit for inrush current is not built in the 24 VDC control power supply. The
protective circuit must be designed by the customer.
* 4. Make sure the current capacity is accurate. For the SERVOPACK with the cooling fan built-
in, an inrush current flows; 200 % of the current capacity in the table above for two seconds,
when turning ON the control circuit power supply to start the fan working.
Note: Do not use a fast-acting fuse. Because the SERVOPACK's power supply is a capacitor
input type, a fast-acting fuse may blow when the power is turned ON.
The SGDH SERVOPACK does not include a protective grounding circuit. Install a ground-fault protector
IMPORTANT
to protect the system against overload and short-circuit or protective grounding combined with the molded-
case circuit breaker.
Current Capacity of the
Molded-case Circuit Breaker
Power Supply
and the Fuse (A
Capacity per
(Refer to 6.8.7)
SERVOPACK
(kVA)
Main Circuit
Power Supply
0.25
0.40
4
0.75
1.2
8
1.4
4
1.9
7
2.3
3.2
10
4.3
13
5.9
17
7.5
28
15.5
41
1.1
1.6
2.3
3.4
3.2
4.6
4.9
7.1
6.7
9.7
10.3
14.9
15.4
22.3
°
C): 300% five seconds min. and inrush current of 20ms.
2.6 Selecting Peripheral Devices
Inrush Current
∗1,∗2
)
rms
Control Cir-
Main Circuit
cuit Power
Power Supply
Supply
0.13
63A
118A
∗4
0.15
63A
67A
∗4
40A
0.27
10A
∗4
0.7
20A
78A
∗4
20A
1.2
Control Cir-
cuit Power
Supply
60A
2
60A
∗3
(24 VDC)
2-11

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgltwSglgwΣ-ii seriesSgdh servopack

Table of Contents