8.2.10 Motor Models Display (Fn011)
This mode is used for motor maintenance, set the parameter Fn011 to select the motor model check mode. If the
SERVOPACK has been custom-made, you can also check the specification codes of SERVOPACKs.
Display after
Step
Operation
1
2
3
4
5
6
7
Digital Operator Panel Operator
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
DATA
ENTER
DATA
(DATA/SHIFT Key)
(DATA/ENTER K ey)
(Press at least 1 s.)
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
DSPL
SET
MODE/SET
(DSPL/SET Key)
(MODE/SET Key)
DATA
ENTER
DATA
(DATA/SHIFT Key)
(DATA/ENTER K ey)
(Press at least 1 s.)
8.2 Operation in Utility Function Mode (Fn
Description
Press the DSPL/SET or MODE/SET Key to select the
utility function mode.
Press the UP or DOWN Key to select Fn011.
Note: The enabled digit blinks.
Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to display the linear ser-
vomotor model and voltage code.
Linear Servomotor Voltage
Linear Servomotor Type
Data
Model
01
200 VAC or 280 VDC
02
400 VAC or 560 VDC
Press the DSPL/SET or MODE/SET Key to display the
servomotor capacity.
Motor capacity in units of 10 W
The above example indicates 100 W.
Press the DSPL/SET or MODE/SET Key, and the linear
scale type and resolution code will be displayed.
Linear Scale Type
Scale Pitch Multiplication
Data
Data
Type
00
Incremental
Press the DSPL/SET or MODE/SET Key to display the
SERVOPACK's code for custom orders.
Note: The display "y.0000" means standard model.
Code for custom orders
Press the DATA/ENTER Key once, or DATA/SHIFT
Key for more than one second to return to the utility
function mode display Fn011.
)
Data
Type
40
Linear servomotor
Resolution
8
8-bit
8-17
8