YASKAWA SGLFW User Manual page 198

Linear σ series servomotors
Hide thumbs Also See for SGLFW:
Table of Contents

Advertisement

7 Wiring
7.1.3 SGLFW and SGLFM Linear Servomotor (F-shaped with Core)
(2) Coil Assembly Installation
The SGLFW coil assembly is constructed of an aluminum or steel base and iron core, with a resin-coated coil
winding section. Make sure that the coil winding section is not subjected to shock during installation. Shock may
cause injury or damage to the coil assembly.
Use the following procedure to install the SGLFW coil assembly.
1. Install the coil assembly on the movable table supported by the linear guide in line with the previously
installed magnetic way.
Make sure that the air gap between the coil assembly and magnetic way magnets is the specified distance.
Magnetic way
Maintain the following air gaps when installing. Make sure that the coil assembly and magnetic way do
not interfere during the stroke.
Coil Assembly
Model
SGLFW-
20
35
50
1Z
* The value in parentheses is the dimension when the magnet protection
cover is used.
7-8
Movable table
Coil assembly
Dimensions is mm (in)
H
P
22 ± 0.2
45 ± 0.1
(0.87 ± 0.004)
(1.77 ± 0.004)
21 ± 0.2
(0.83 ± 0.004)
25.8 ± 0.2
58 ± 0.1
(1.02 ± 0.004)
(2.28 ± 0.004)
27 ± 0.2
(1.06 ± 0.004)
Installation tap
Air gap G
assembly
1 ± 0.3
(0.04 ± 0.01)
Magnetic way
(0.8 (0.03))
Linear servomotor side
(Diagram viewed from the side where the
cable extends from the coil assembly.)
P
Cable
Coil
Standard
mark

Hide quick links: