2.6.4 Regenerative Resistors

Main Circuit
Power Supply
Single-phase
200 V
Three-phase
200 V
Three-phase
400 V
* 1. For the optional JUSP-RA05 Regenerative Resistor Unit.
* 2. For the optional JUSP-RA18 Regenerative Resistor Unit.
Note: 1. If the SERVOPACK cannot process the regenerative power, an external regenerative resistor is
required. Refer to 6.8.5 External Regenerative Resistor, 6.8.6 Regenerative Resistor, and 7.6
Connecting Regenerative Resistors.
2. The following table shows the manufacturers of each device.
Peripheral Device
External Regenerative Resistor
External Regenerative Unit
SERVOPACK Model
Capacity
SGDH-
Resistance
(kW)
(Ω)
0.05
A5AE
0.10
01AE
0.20
02AE
0.40
04AE
0.45
05AE
0.75
08AE
1.0
10AE
1.5
15AE
2.0
20AE
3.0
30AE
12.5
5.0
50AE
7.5
75AE
(3.13)
0.45
05DE
1.0
10DE
108
1.5
15DE
2.0
20DE
3.0
30DE
5.0
50DE
7.5
75DE
(18)
Iwaki Wireless Research Institute
Yaskawa Electric Corporation
Regenerative Resistor
(Refer to 6.8.5, 6.8.6, and 7.6.)
Built-in
Externally
Capacity
connected
(W)
50
60
30
70
25
140
140
8
280
∗1
∗1
JUSP-RA05
(1760)
70
45
140
32
180
∗2
∗2
JUSP-RA18
(880)
Manufacturer
2.6 Selecting Peripheral Devices
2
2-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SgltwSglgwΣ-ii seriesSgdh servopack