9 Operation

9.11.4 Force Limiting Using an External Force Limit and Analog Voltage Reference

9.11.4 Force Limiting Using an External Force Limit and Analog Voltage Reference

This function can be used to combine force limiting by an external input signal and by analog voltage reference.
Because the force limit by analog voltage reference is input from T-REF (CN1-9, 10), this function cannot be
used during force control. Use /P-CL (CN1-45) or /N-CL (CN1-46) for force limiting by external input signal.
When /P-CL (or /N-CL) is ON, either the force limit by analog voltage reference or the setting in Pn404 (or
Pn405) will be applied as the force limit, whichever is smaller.
/P-CL
/N-CL
Force limit
value
Speed
reference
(1) Related Parameters
Parameter
Pn002
n.
When n.
Pn404
Forward External Force Limit
Pn405
Reverse External Force Limit
* The setting unit is a percentage of rated force (i.e., the rated force is 100%).
9-72
SERVOPACK
T-REF
Pn400
+
V-REF
Pn300
-
Speed feedback
3
Speed control option: When /P-CL or /N-CL is enabled, the T-REF terminal is used as the
external torque limit input.
2 is set, T-REF is used for force feed-forward input, but the functions cannot be used together.
Setting Range
0 to 800
Setting Range
0 to 800
Speed loop
+
gain
(Pn100)
+
Speed loop
integral
Reverse torque
time
Pn405
constant
limit value ( Pn484 )
( /N-CL : ON)
(Pn101)
Meaning
Setting Unit
%
Setting Unit
%
Forward torque
limit value (Pn483)
Pn404
( /P-CL: ON )
Force
reference
Speed
Position
Factory Setting
Setting Validation
100
Factory Setting
Setting Validation
100
Force
Immediately
Immediately