Battery for Absolute Encoder
Note: No battery is mounted in the battery
case. A battery must be purchased separately.
2.5.2 Molded-case Circuit Breaker and Fuse Capacity
Main Circuit
Power Supply
Single-phase
100 V
Single-phase
200 V
Three-phase
200 V
* 1. Nominal value at the rated load. The specified derating is required to select an appropriate
fuse capacity. Refer to 4.4.8 Molded-case Circuit Breaker (MCCB).
* 2. The cutoff characteristics (25
Note: Do not use a fast-acting fuse. Because the SERVOPACK's power supply is a capacitor
input type, a fast-acting fuse may blow when the power is turned ON.
The SGDS SERVOPACK does not include a protective grounding circuit. To ensure safety in the system,
IMPORTANT
install a ground-fault protector against overloads and short-circuit, or a ground fault protector dedicated for
protective grounding combined with the molded-case circuit breaker.
Name
JUSP-BA01
JZSP-BA01
ER6VC3N
SERVOPACK Model
Power Supply Capacity
per SERVOPACK
Capacity
SGDS-
(kW)
0.05
A5F
0.10
01F
0.20
02F
0.40
04F
0.05
A5A
0.10
01A
0.20
02A
0.40
04A
0.75
08A
1.0
10A
1.5
15A
2.0
20A
3.0
30A
°
C): 200% two seconds min., 700% 0.01 seconds min.
Type
Specifications
Battery case
(To mount in the battery case)
To connect to a host controller (provided by a
customer)
3.6 V 2000 mAh,
manufactured by Toshiba Battery Co., Ltd.
Current Capacity of
Breaker or Fuse
(kVA)
(A
rms
0.25
0.40
0.60
1.2
0.25
0.40
0.75
1.2
2.1
2.3
3.2
4.3
5.9
2.5 Selecting Peripheral Devices
∗1,∗2
)
4
6
12
4
8
16
7
10
13
17
2-25