12 Appendix
12.4.2 List of Parameters
Parameter
No.
Pn510
Output Signal Selection 3
4th
3rd
digit
digit
n.
Pn512
Output Signal Reverse Settings
4th
3rd
digit
digit
n.
* Available for the software version 32 or later
12-38
Name
2nd
1st
digit
digit
Near Signal Mapping (/NEAR)
0
Disabled (the above signal is not used.)
1
Outputs the signal from CN1-25, -26 terminal.
2
Outputs the signal from CN1-27, -28 terminal.
3
Outputs the signal from CN1-29, -30 terminal.
Reserved (Do not change)
Reference Pulse Input Switch Signal Mapping (/P-SELA)
0 to 3 Same as /NEAR
Reserved (Do not change)
2nd
1st
digit
digit
Output Signal Reverse for CN1-25 or -26 Terminals
Output signal is not reversed.
0
1
Output signal is reversed.
Output Signal Reverse for CN1-27 or -28 Terminals
0
Output signal is not reversed.
1
Output signal is reversed.
Output Signal Reverse for CN1-29 or -30 Terminals
0
Output signal is not reversed.
1
Output signal is reversed.
Reserved (Do not change)
Setting Range
Unit
Factory
Setting
Setting
Validation
0000
After
restart
0000
After
restart
Reference
Section
9.8.6
8.3.3