Initial Settings for Online Connections
FinsGateway service
Node PLCs
Direct FinsGateway
Online Connections
1, 2, 3...
246
2. Click the Find Button. The Loop Control Units on networks of the PLC to
which the CX-Process is connected will be found and the cursor will move to
the Loop Control Unit that was found.
Finds a Loop Control Unit.
Updates and reconfigures the display.
3. Keep on pressing the Find Button to find the next Loop Control Unit.
Note Although it is possible to search for a Loop Control Board as well, the
unit address is always 255 and thus Loop Control Boards are not sup-
ported by this function.
4. To register the addresses of a selected Loop Control Unit, click the Select
Button. The addresses will automatically be set for the LCU element.
To make initial settings for direct FinsGateway online connections, take the fol-
lowing steps. Refer to the FinsGateway Operation Manual for details.
1. Serial Settings
Make necessary settings, such as personal computer communications port,
node address, and protocol (serial communications mode) settings.
Section
Network address
FINS address
Cursor will move to Loop
Control Unit.
Unit at nodes are displayed.
Sets the addresses for the current
Loop Control Unit and sets them
for the LCU element.