Using SCADA Software
Select this option when compiling an RS
View tag file that is saved on a remote OPC
Server, i.e., a OPC Server on the network.
Input the computer name and IP address of
the remote server.
This option is used when there is no OPC
Server installed on the local computer or
when all information management is being
performed on one OPC Server.
To use this option, any RS View tag file
output on the local computer must be
transferred to the remote server. A file on a
client cannot be complied by the remote
server. Refer to the SYSMAC OPC Server
Operation Manual for information on
designating remote servers.
Note Specify the data settings for tag com-
pilation, the OPC tag file name, and
the file name for creating the RS View
CSV tag file using absolute paths on
the remote server.
3. Set the folder and name for the tag file and click the OK Button. The following
RS View Tag Compile Dialog Box will appear.
When specifying a SCADA tag file (Taglist.csv) for compilation,
select this option and specify the SCADA tag file.
If this option is selected:
The OPC Server group name will be the same as the CSV tag file
tag name (representative tags) and the OPC Server tag name will
be the same as the CSV tag file ITEM tag name.
If this option is not selected:
The OPC Server tag name will be the same as the CSV tag file
tag name (representative tags) and the ITEM name will be added
after an underscore.
Select this option to add the symbol information for the symbols for
all local symbol tables in the current CXP project for
CX-Programmer running on the same computer.
Specify the location for automatic generation of the OPC tag
settings file (.sbd) (the OPC Server binary file).
Specify the output folder and file name for the RS View tag file.
Use the file specified here to import the CX-Process Tool tags to the
RS View 32 tag data base. Use the Database Import and Export
Wizard to execute the import operation.
Specify the node name set for the OPC Server in the RS View 32
project.
Specify the type of file to output.
Tag: Tag data only
Tag + Min/Max + unit: Tag data plus additional information (See note.)
Note The additional information includes scaling information (scaling
Specify the group level. If a level is not specified, all tags will be
output. Tags in groups beyond the specified group level will not be
output.
Specify process when array data is being output.
Select this option to convert integer data on the OPC Server to the
default data type (real) on the RS View 32.
Select this option to disable data in the OPC Server between
+115% and 100% and between –15% and 0%. This option treats
data in the range +115% to 100% as 100% and data in the range
–15% to 0% as 0%.
For example, the data range for PID function block item HH is
–15.00 to +115.00, but data in the range +100% to +115% and
–15% to 0% will be ignored and only data between 0% and 100%
will be used.
4. The following dialog box will appear if tag file was compiled correctly.
5. Click the OK Button.
upper/lower limits and decimal point position), units, and data
range upper/lower limits (calculated using scaling information).
Section
3-4
153