5.2

General Timing Management

To ease the configuration of the device the WRZ-OS implements presets to allow
a quick setup of the timing sources and of the master ports to redistribute time.
5.2.1

Presets

Preset configuration is found in the Web GUI under Configuration > Timing Gen-
eral > Preset.
5.2.1.1

WR Slave @ wr0 (BC) [default]

Web GUI selection: BC: wr0 | WR
This is the default preset as it is the standard/legacy configuration of most of the
WR devices. This is the simplest Boundary Clock behavior where the device is dis-
CHAPTER
5
WR-ZEN Series User Manual Rev. v5.1
   0.8500.2   spll/survey/gm_phase_ready           : 1                   
gm_phase: Phase difference between the external 10 MHz reference and the
internal clock.
gm_phase_ready: Defines if the gm_phase value is ready to be read.
Note:
If the device has been shipped with the holdover option, this
timing source will be, by default, configured as the last timing source
independently of the preset.
Note:
PTP Master configuration: Presets only configure the role and
protocol (PTP or WR) used for all network interfaces with some
default settings. A specific configuration of PTP (e.g., Profile, packet
rates, etc.) can then be performed under the PTPv2 configuration
tab if a valid license has been detected.
The primary timing source is provided using WR protocol through interface
wr0.
The other (wr1) is configured as WR master.
5.2  General Timing Management