5.7.2

Info/Overview

An overview of the holdover timing source is provided to monitorize its state at
any time as shown in
If its state is UNAVAILABLE this means that the holdover oscillator has not been
detected and its related information in irrelevant. If you have ordered the hold-
over option but the device does not detect it, please contact
on
Figure 5-18:
3.7220.x
CHAPTER
5
WR-ZEN Series User Manual Rev. v5.1
Note:
HO in between timing source: Using the source rank the HO
can be placed between two timing sources. For example, the user
can use WR as primary timing source, HO as secondary and PTP
8265.1 as third one. This means that if WR fails, the device will enter
in HO until expiration and finally switch to PTP that might provide
better accuracy than an expired HO.
"Holdover overview"
page 188.
Holdover overview
OID
Name
holdover/info/xxx
below.
Value Type
Information about the Holdover
timing source
5.7  Holdover
"Technical Support"
Description