Table 9-1:
Additional regional contact information can be found on the
Safran Trusted 4D website.
9.4

VCS Code

The Virtual Clock Status Code has been created to easily identify the timing
status of a device and easily troubleshoot in case it has failed. The VCS code are
also used by the FOCA algorithm to detect a failure within a timing source and
switch to the next available one.
9.4.1

Grand Master (GM VCS Code)

A device in Grand Master is when the timing source is external (i.e., 10MHz/PPS)
or from a non-PTP source such as GNSS.
VSC
VSC-
10000
VSC-
10101
VSC-
10102
VSC-
10103
WR-ZEN Series User Manual
Safran contact information
Device
HO
Message
Status
OK
Locked
CRITICAL
Unlocked:
10MHz not
present
CRITICAL
Unlocked:
PPS not
present
CRITICAL
Unlocked:
10MHz+PPS
not present
Contact page
Clock
Active
Class
Reference
6
GM: Front-
Everything is OK for GM
panel
device
187
GM: Internal
The 10MHz signal is not
Oscillator
properly connected to
the GM (or provide too
low voltage, bad fre-
quency, etc...)
187
GM: Internal
The PPS signal is not
Oscillator
properly connected to
the GM (or provide too
low voltage)
187
GM: Internal
10MHz and PPS signals
Oscillator
are not properly con-
nected to the GM (or
provide too low
voltage)