QWIK‑PURE
®
iCS
10.3 Maintenance work
For maintenance work to be carried out, the following prerequisites must be fulfilled and the respective
preparatory tasks must have been completed.
10.3.1 Turbidity test of the purified condensate
Tool
•
No tool necessary
Image
92 | 132
Preconditions
Material
•
No material necessary
1. Remove the reference turbidity tube from the
holder and fill it with a water sample from the
service valve.
2. Compare the sample with the reference turbidity
on the lower half of the reference turbidity tube.
The sample is clearer than the reference turbidity:
0 The QWIK-PURE
The sample is equally or more turbid than the
reference turbidity
0 Replace the filter cartridges immediately.
3. Document the result of the turbidity test.
Installation and operating manual
Protective equipment
To be worn at all times:
Description
iCS is working perfectly.
®