Beko QWIK-PURE CS Installation And Operating Manual page 98

Table of Contents

Advertisement

QWIK‑PURE
®
iCS
Image
98 | 132
Description / explanation
16. After replacing the filter cartridges, press and 
hold down the Enter button for 3 seconds.
0 The piston in the FRC will open the
condensate inlet from the pressure relief
chamber into the FRC.
3 sec
0 The status LED STATUS BAR lights up green.
0 The display will switch to the START MENU
screen.
17. Remove the cover from the pressure relief
chamber and remove the activated carbon mat
from the vent of the pressure relief chamber.
18. Dispose of the activated carbon mat properly
(see section "14. Disposal" on page 122).
19. Lift the filter cartridge out of the collector and 
dispose of it properly (see section "14. Disposal"
on page 122).
20. Fill the QWIK-PURE
vent.
0 Stop filling as soon as the FRC performs a
discharge operation.
21. Insert the new activated carbon mat into the
vent of the pressure relief chamber and place the
cover on the pressure relief chamber.
22. Slowly open the condensate feed.
23. Check all hoses and connections for leaks (see
section "10.3.7 Leakage test" on page 109).
Installation and operating manual
iCS with tap water via the
®