Maintenance Plan - Beko QWIK-PURE CS Installation And Operating Manual

Table of Contents

Advertisement

Installation and operating manual
WARNING
WARNING

10.2 Maintenance plan

Maintenance
Turbidity test of wastewater and documenting the
result
Visual inspection
Replace the filter cartridges and activated carbon 
mat
Replace the piston
Replace solenoid valves
Leakage test
Insufficient qualification!
If personnel have insufficient qualifications, this may result in accidents, personal 
injury and property damage as well as operating disruptions while working on the
product or its accessories.
All work on the product and accessories may only be carried out by professional
technicians - Service.
Ingress of moisture or foreign objects!
Water and foreign objects can get into the opened FRC control unit or into the
opened electrical connections if electrical connections are disconnected or if
the FRC control unit is opened. The ingress of water or foreign objects can result in
accidents, personal injury and property damage, and problems during operation.
Protect the FRC control unit and the electrical connections from splash water
and moisture.
Open the FRC control unit and disconnect the electrical connections in a dry
location only.
Do not insert any foreign objects into the openings of the FRC control unit.
Keep all contact surfaces and openings free of impurities and moisture.
Interval
Weekly
Weekly
Mandatory in case of a negative result of the
turbidity test
Maximum lifetime of the filter cartridges 
reached, see section "9.2.3 Querying filter 
cartridge status"
At least annually
Maximum lifetime of the piston reached, see
section "9.2.5 Querying piston status"
At least every two years
Maximum lifetime of solenoid valves reached,
see section "9.2.4 Querying the solenoid valve
status"
At least every six years
Recommendation: After all assembly and
maintenance work on the product