Installation work
Description / explanation
18. Slide the pressure relief chamber as far away
from the measuring chamber as possible.
19. Check the sealing surfaces on the measuring
chamber for damage and dirt.
0 Remove any dirt.
0 If there is any damage, contact
BEKO TECHNOLOGIES Service (see section
"1.1 Contact" on page 5).
20. Apply a thin layer of the Vaseline supplied to the
O-ring on the FRC.
21. Align the FRC with the assembly opening in the
measuring chamber and insert it.
22. Turn the FRC clockwise until the FRC connection
is aligned with the pressure relief chamber
connection.