QWIK‑PURE
®
iCS
Image
3 sec
116 | 132
Disassembly work
Description / explanation
The current status of the filter cartridges is
displayed.
0 The status LED FILTER CARTRIDGES will
flash red.
0 The status LED STATUS BAR lights up red.
3. Press and hold the Service button for 3 seconds.
The discharge process is started.
0 The piston in the FRC will close the
condensate inlet from the pressure relief
chamber into the FRC.
0 The measuring chamber is supplied with
auxiliary air at timed intervals.
0 The condensate is passed into the filter
cartridges. This takes several minutes.
0 The status LED STATUS BAR flashes blue and
indicates the remaining time until the filter
cartridge needs to be removed.
Status LED STATUS BAR
4/4 of the length flashes blue
3/4 of the length flashes blue
2/4 of the length flashes blue
1/4 of the length flashes blue
When the remaining time has elapsed, the discharge
process stops.
0 The status LED STATUS BAR lights up blue.
0 The measuring chamber is no longer
pressurized with auxiliary air.
Installation and operating manual
Remaining time
100%
75%
50%
25%