Frc Operating Parameters - Beko QWIK-PURE CS Installation And Operating Manual

Table of Contents

Advertisement

Installation and operating manual

4.2 FRC operating parameters

Parameter
Relative ambient humidity
Maximum operating height
Minimum / maximum operating 
pressure, compressed air
*2
Contamination class
, compressed air
Minimum / maximum operating 
temperature, fluids and environment 
Connection, compressed air
Operating voltage
Frequency range
Power consumption
Degree of protection
Enclosure rating (UL50E)
Overvoltage category (IEC 61010-1)
Degree of pollution (IEC 61010-1)
Recommended cable diameter, power
supply
Recommended wire cross-section,
power supply
Recommended cable type, power supply
Recommended maximum cable length,
power supply
WLAN standard
WLAN frequency range
Maximum WLAN transmission power
WLAN encryption
*2
contamination class in conformity with ISO 8573-1
FRC control unit
≤10 ... 80%, without condensate
2000 m
2187.23 yd
3 ... 15 bar(g)
44 ... 218 psi(g)
[2 : 4 : 2]
+5 ... +50 °C
+41 ... +122 °F
Hose connection
8 mm (0.31 in), male
90 ... 264 VAC / 24 VDC 
(See type plate on the FRC control unit)
50 ... 60 Hz
28 VA
IP54
Type 13
II
2
8 ... 10 millimeters
0.32 ... 0.33 in
0.75 to 1.5 mm²
20 ... 16 AWG
EU: H05VV-F 3G
US: SJT
3 m
10 ft
IEEE 802.11 n/g/b
2.4 GHz
(24120 ... 2462 MHz)
19.5 dBm / 89 mW
WPA2-PSK
QWIK‑PURE
iCS
®
43 | 132

Advertisement

Table of Contents
loading

Table of Contents