4. Technical data

4.1 QWIK‑PURE
®
Parameter
Relative ambient air humidity
Maximum operating altitude above sea
level
Maximum operating pressure at
condensate inlet
Minimum / maximum operating 
temperature, fluids and environment 
Maximum condensate flow rate
Condensate inlet port
Condensate drain port
Fluids
Maximum operating weight
Maximum oil concentration at
*1
condensate drain port
*1
Performance data according to national technical approval issued by DIBt (Deutsches Institut für
Bautechnik)
42 | 132
iCS operating parameters
19 l/h
*1
5.02 gal/h
55 kg
121.3 lbs
QWIK-PURE
550
1100
≤10 ... 80%, without condensate
2187.23 yd
16 bar(g)
230 psi(g)
+5 ... +50 °C
+41 ... +122 °F
38 l/h
10.04 gal/h
 3 x G1/2", male,
1 x G1", male,
Hose connection:
1 x 25 mm (0.98 in), male,
1 x 13 mm (0.52 in), male
25 mm (0.98 in), male
hose connection
Compressor condensate, oil-contaminated
100 kg
220.5 lbs
10 mg/l
Installation and operating manual
iCS
®
2200
2000 m
76 l/h
20.08 gal/h
30.12 gal/h
180 kg
396.8 lbs
10 ppm
3300
114 l/h
250 kg
551.2 lbs