Installation and operating manual
Image
Description / explanation
The discharge process is started.
0 The piston in the FRC will close the
condensate inlet from the pressure relief
chamber into the FRC.
0 The measuring chamber is supplied with
auxiliary air at timed intervals.
0 The condensate is passed into the filter
cartridges. This takes several minutes.
0 The status LED STATUS BAR flashes blue and
indicates the remaining time until the filter
cartridge needs to be changed.
Status LED STATUS BAR
4/4 of the length flashes blue
3/4 of the length flashes blue
2/4 of the length flashes blue
1/4 of the length flashes blue
When the remaining time has elapsed, the discharge
process stops.
0 The status LED STATUS BAR lights up blue.
0 The measuring chamber is no longer
pressurized with auxiliary air.
4. Turn the end caps on the filter cartridges
anticlockwise and remove them.
0 Put the end caps to the side, as they will be
screwed back on the new filter cartridges.
QWIK‑PURE
iCS
®
Remaining time
100%
75%
50%
25%