Problem
Problem
no.
Not possible to change
7
to forced output mode.
The Wireless Remote
unit does not operate
8
with the set input / output
size.
The location and the type
9
of error being generated
is unknown.
Free Remotes are not
10
displayed when
registering the Remote.
Possible causes
1. Connected with higher
unit.
2. Mode is Monitor mode.
The Wireless Remote
operates with the input /
output size set when the
Wireless Remote was
registered.
-
1. The Wireless Remote is
not in pairing mode.
2. The Wireless Remote is
already registered.
3. Another Wireless Base is
in pairing mode.
-141-
Inspection and countermeasures
1. Disconnect the unit from the higher unit.
2. Login from the Administrator mode.
The Wireless Remote follows the input /
output size when it was registered to the
Wireless Base. Check the Wireless Remote
input / output size from the Wireless Base. If
the size is not correct, register the size
again.
Check the system configuration on the
Information tab of the Wireless Base to
identify the unit with an error. Check the
diagnostic information from the Description
to identify the error. Refer to "5.1 Information
tab" for details and diagnostic information of
each unit.
1. Check that the Wireless Remote is in
registration mode.
2. When the Wireless Remote is already
registered, it needs to be deleted to register
it again.
3. When another Wireless Base is in pairing
mode, the Wireless Remote will be displayed
for the Base. Keep to having one Wireless
Base in pairing mode.
No.EX##-OMV0017-G