Contents 1. Introduction 1.1. Definition and terminology 2. Preparation before use 2.1. Software Installation 2.2. Before starting the software 2.3. Download the I/O Configurator (NFC version) 2.4. Start the I/O Configurator 3. Window of I/O Configurator (NFC version) 3.1. Basic characteristics 3.1.1.
Page 3
5. Pairing of wireless unit 5.1. Pairing procedure of wireless unit 5.2. Registration of dummy Remote 6. Wireless system configuration example 6.1. Flow chart for using the wireless system (Refer to Step 2) 6.2. System Construction Example 6.3. Preparation 6.4. (1) Input and output size of the Wireless Remote 6.5.
1. Introduction This operation manual describes the installation, construction of screens and operation method of the I/O configurator for NFC. The SMC wireless system I/O Configurator for NFC can be used to check the parameter setting of the wireless unit and the contents and status of the constructed wireless system, using an NFC reader/writer and a PC.
Page 5
: About the communication timing The NFC communication is not accessed all the time. Therefore, it is necessary to update the contents displayed on the screen by clicking the "Refresh button" when reading the parameters. The parameters changed are valid after re-supplying the power supply or by pressing the reset button in the I/O Configurator screen.
1.1. Definition and terminology Term Definition Administrator mode Administrator mode allows the user to configure the wireless units. A broken wire to the input or output equipment has been detected by the diagnostic Broken line detection function. A protocol that automatically allocates information, necessary to be registered to use DHCP the network, such as an IP address, to individual devices connected to the TCP/IP network.
Page 7
Term Definition Occupied points for the module Number of I/O points that can be controlled by a module. input/output Registration of the PID (Product ID) of the Wireless Remote unit to be connected to the Paring Wireless Base unit. Registration occurs at the initial setting, then wireless system will activate.
2. Preparation before use 2.1. Software Installation Driver: The following drivers should be installed before using this software. When the SONY Corporation RC-S380/S NFC reader is used (1): Microsoft. Net Framework 4.0 or higher https://www.microsoft.com/en-US/download/details.aspx?id=17718 (2): NFC reader, writer connection driver NFC port software (Ver 5.6.0.2 / Approx.40 MB / July.25.2017) https://www.sony.net/Products/felica/business/products/RC-S380.html When the Advanced Card Systems Ltd.
2.2. Before starting the software When the SONY Corporation RC-S380 NFC reader is used, set up the NFC port following the procedure below. When the Advanced Card Systems Ltd. ACR1251U/ACR1252U NFC reader is used, the following setting procedure is not necessary. (1) Double-click the [NFC port/PaSoRi] icon on the control panel to display the setting window.
2.3. Download the I/O Configurator (NFC version) (1) On the SMC website (https://www.smcworld.com/), select the Documents/Download and select the Instruction Manuals. (2) Select the Fieldbus System Serial Transmission System. No.EX※※-OMV0017-C...
(3) Select the protocol that the product supports. (Example: EtherNet/IP™ compatible) (4) Scroll down the page of the Fieldbus System Serial Transmission System and select the Configuration File of I/O configurator for NFC. Downloading will begin. 2.4. Start the I/O Configurator (NFC version) Open the downloaded file and double click the IOConfigurator.exe to start the I/O configurator for NFC.
3. Window of I/O Configurator (NFC version) In this chapter, the screen display in I/O Configurator (NFC version) in Wireless Base/Remote will be explained. 3.1. Basic characteristics The window below is displayed when the I/O configurator for NFC starts. Place the NFC reader/writer within 1 cm of the centre of the wireless symbol on the wireless unit to display the Wireless Base/Remote information and change the parameter setting.
Page 13
•Basic characteristics Item Explanation When the SONY Corporation RC-S380/S NFC reader is used. NFC setting button When the NFC setting button is clicked, "NFC port/PaSoRi" is displayed on the setting screen. (Refer to 2.2 Before starting the software. (page 8)) The I/O configurator for NFC software version appears by clicking the question mark.
3.1.1. Login to administrator mode Password is necessary to login to the Administrator mode. In administrator mode It is possible to change the password using "Edit password". For security, change the password for the first time of access. Default password: admin Password check window will open by clicking the Administrator mode.
3.2. Display for Wireless Base The tabs available on the upper left of the I/O configurator for NFC consists of the Information (page 14), I/O monitor (page 16) and Properties (page 20). 3.2.1. Information tab The Information tab consists of Unit information, System Configuration and Description. Unit information Description...
Page 16
3.2.1.2 System Configuration shows the configuration information of the Wireless Base/Remote module. System configuration Wireless Base unit Unit selection Dummy Remote (reserved) Error is indicated Wireless Remote In System configuration, connected I/O units can be checked by clicking on the displayed wireless unit. 3.2.1.3 Description Description about the unit selected in the System configuration.
3.2.2. Input/Output monitor tab In the I/O monitor tab, the wireless unit I/O map data can be monitored. Diagnosis information or details of input/output can be checked by double clicking each line in the display. 4.3. Forced output Forced output mode ( (page 60)) can be selected within the Output tab.
Page 18
3.2.2.2. Output tab Output tab shows the output map information of the wireless unit. •Output display Description Content Displayed items Forced output mode can be selected by clicking Enforce ON. Checked : Enforce ON Enforce ON : Refer to 4.3 Forced output (page 60) for the operation. Unchecked : Enforce OFF ADRS Displays the input map address.
Page 19
3.2.2.3. I/O Detail I/O Detail will open by double clicking the line of the desired address of I/O unit which is connected to the wireless unit. Double-click -18- No.EX※※-OMV0017-C...
Page 20
IO unit information, IO data & diagnostics can all be checked in the IO Detail window. Diagnostic error type is represented by different background colours. The meaning of background colour can be checked by clicking [>>]. •Background colour Background Error Description colour Detection of unconnected load...
3.2.3. Setting tab The configuration of the connected unit can be changed using the setting tab. It consists of setting items (page 21) and the setting display (page 22) (Base setting, Ethernet setting, Remote registration and System setting). Set item Setting display -20- No.EX※※-OMV0017-C...
Page 22
3.2.3.1. Setting items area Control panel for setting consists of 4 radio buttons and 3 buttons. •Radio buttons for selecting the required setting window. Description Function Switch to the Base unit setting window. Occupied points for the module input/output can be Base setting set.
Page 23
3.2.3.2. Setting display (1) Base setting The Base setting window. -22- No.EX※※-OMV0017-C...
Page 24
•Base setting items Description Explanation Define all settings in the output operation status when the Fieldbus communication is disconnected. CLEAR: Clear the output. Hold/Clear (unit) HOLD: Fix the output at the current value. Software control: Clear, Hold or Set for individual points can be set by software bit. : For details of the Software Control.
Page 25
(2) Ethernet setting Ethernet setting display. (EX600-WEN# only) •Ethernet setting items. Description Explanation MAC address MAC address of the product is displayed. Select the IP address setting mode. Select the mode suitable for your network environment. Manual : The IP address is set by inputing it directly.
Page 26
(3) System setting System setting display. -25- No.EX※※-OMV0017-C...
Page 27
Wireless channels for the number of the set units are valid. Max. Remote units Setting range EX600-WEN# : 0/15/31/63/127 pcs. EX600-WPN# : 0/15/31 pcs. Set the data update time of the analogue output unit connected to the Wireless Remote. Setting range: 0.1/0.2/0.5/1/2/5/10/30/60 s (Initial value 1 s) : The analogue input update time can also be set for every Wireless Remote unit.
Page 28
(4) Remote registration Registration for wireless communication between the Wireless Base unit and the Wireless Remote unit. For this wireless system, it is necessary to register the PID for each product to establish communication without interference from another network. The window for Remote registration consists of Registered Remotes, Save reg.
Page 29
(4-2) Save registration buttons Buttons used for Remote registration. Remote registration buttons are only available when wireless units are in pairing mode. •Remote registration buttons Description Content Select the wireless channel used to register the Remote to the Wireless Base. W.ch (Only channels available for registration will be displayed) Button to move the Wireless Remote from Free Remotes to Registered Remotes.
Page 30
(4-4) Pairing Details of Pairing. The radio buttons used for pairing are only available in Administrator mode. They can only be set when power is not supplied. •Details of pairing radio button Description Explanation Button to change to Normal (non-pairing) mode. Indicates that the current status is Normal Normal mode (pairing disabled) mode.
3.3. Display for Wireless Remote The tabs available at the upper left of the I/O configurator for NFC window consists of the Information (page 30), Input/Output monitor (page 32) and setting (page 36). 3.3.1. Information tab The tab for Information consists of Unit information, System configuration and Description. Unit information Description...
Page 32
3.3.1.2. System Configuration area System configuration shows the configuration information of the Wireless Remote module. Error display: Error is indicated. In System configuration, connected I/O units can be checked by clicking the Wireless Remote unit. 3.3.1.3. Description area Description of the unit selected in the System configuration area is displayed. : Description varies depending on the unit type.
3.3.2. Input/Output monitor tab In the I/O monitor tab, the wireless unit I/O map data can be monitored. Diagnostic information or details of input/output can be checked by double clicking the line in the display. It is possible to switch between input map and ouput map using the tabs shown.
Page 34
3.3.2.2. Output tab Output tab shows the output map information of the wireless unit. •Output display Description Content Displayed items Forced output mode can be selected by clicking Enforce ON. Checked : Enforce ON Enforce ON : Refer to 4.3 Forced output (page 60) for the operation. Unchecked : Enforce OFF Address Displays the output map address of the Wireless Remote.
Page 35
3.3.2.3. IO Detail IO Detail will open by double clicking the line of the required address of the IO unit which is connected to the wireless unit. Double-click -34- No.EX※※-OMV0017-C...
Page 36
IO unit information or IO data & diagnostics can be checked in the IO Detail window. The Diagnostic error type is represented by different background colours. The meaning of background colour can be checked by clicking [>>]. •Background colour Background Description Description colour...
3.3.3. Setting tab The configuration of the connected unit can be changed using the setting tab. It consists of setting items area (page 37) and setting window (page 38) (Remote setting and Pairing setting). Setting items Setting display -36- No.EX※※-OMV0017-C...
Page 38
3.3.3.1. Setting items area Control panel for setting consists of 2 radio buttons and 3 buttons. •Radio buttons for selecting the setting window. Description Function Switch to the Remote setting display. Occupied points for the module input/output can be Remote setting set.
Page 40
•Remote setting items Item Explanation Define all settings in the output operation status when the Fieldbus communication is disconnected. CLEAR: Clear the output. Hold/Clear (unit) HOLD: Fix the output at the current value. Software control: Clear, Hold or Set for individual points can be set by software bit. : For details of the Software Control refer to 4.2 Software Control (page 57) for setting in I/O Configurator for NFC) Input size...
Page 41
(2) Pairing setting Setting for wireless communication between the Wireless Base unit and Wireless Remote unit. It is necessary to set the operation mode to Pairing setting when registering the Wireless Remote to Wireless Base. Pairing setting display. •Radio button for selecting Pairing mode. Description Explanation Button to change to Normal (non-pairing) mode.
3.4. Detailed information of units 3.4.1. Information tab Each EX600 unit stores its specific information. The information of the unit connected to the Wireless Base/Remote module can be monitored usig the I/O configurator for NFC. The EX600 unit is accessed using the information tab. Procedure for detailed information Information tab ...
Page 43
3.4.1.1. Wireless unit Detailed information of the main body and valve can be checked in the wireless unit. 1) Main body : Refer to 4.1 Edit the tag •Detailed Information (main body) Description Content Part No. Wireless unit product number Wireless unit PID Wireless unit user memo The wireless unit status is displayed in 4 bytes of hexadecimal number.
Page 44
2) Valve •Detailed information (valve) Description Content Part No. Wireless Base/Remote product number Mapped position for the valve. Displays the mapped position of the selected valve. : Refer to the "Unit address order" of Base setting (page 22) or Remote setting (page 38) for mapping Unit No.
Page 45
3.4.1.2 Digital input unit Digital input unit (product number: EX600-DXD) • Detailed information (digital input unit) Description Content Part No. Displays the product number of the digital input unit which is selected. Displays the mapped position of the selected digital input unit. : Refer to the "Unit address order"...
Page 46
3.4.1.3. Digital output unit Digital output unit (product number: EX600-DYB) • Detailed information (digital output unit) Description Content Part No. Displays the product number of the selected digital output unit. Displays the mapped position of the selected digital output unit. : Refer to the "Unit address order"...
Page 47
3.4.1.4. Digital I/O unit Digital output unit (product number: EX600-DMF) • Detailed information (digital input/output unit) Description Content Part No. Displays the product number of the selected digital input/output unit. Displays the mapped position of the selected digital input/output unit. : Refer to the "Unit address order"...
Page 48
3.4.1.5. Analogue input unit Analogue input (product number: EX600-AXA) Status display: No alarm: (OK) Alarm generated: (Details of error) : Refer to 8.Error Code List on page for details of errors. •Detailed information (analogue Input unit) Description Content Part No. Displays the product number of the selected analogue input unit.
Page 49
3.4.1.6. Analogue output unit Analogue output (product number: EX600-AYA) Status display: No alarm: (OK) Alarm generated: (Details of error) : Refer to 8. Error Code List on page details of errors. • Detailed information (analogue output unit) Description Content Part No. Displays the product number of the selected analogue output unit Displays the mapped position of the selected analogue output.
Page 50
3.4.1.7. Analogue I/O unit Analogue input/output unit (product number: EX600-AMB) Status display: No alarm: (OK) Alarm generated: (Details of error) : Refer to 8. Error Code List on page for details of errors. • Detailed information (analogue I/O unit) Description Content Product No.
3.4.2. Details of I/O monitor tab By clicking the IO Detail tab, the information of the selected unit, diagnostic status, Byte or Bit value , or analogue input/output can be checked. Procedure to display the details of IO unit information I/O monitor tab ...
Page 52
3.4.2.2. Digital input unit Digital input unit (product number: EX600-DXD) • IO unit information (digital input unit) Description Content Displays the PID of Wireless Base/Remote to which the digital input unit is connected. Displays the tag of Wireless Base/Remote to which the selected digital input unit is connected. Displays the channel name of Wireless Base/Remote to which the selected digital input unit is Wireless channel connected.
Page 53
3.4.2.3. Digital output unit Digital output unit (product number: EX600-DYB) • IO unit information (digital output unit) Description Content Displays the PID of Wireless Base/Remote to which the selected digital output unit is connected. Displays the tag of Wireless Base/Remote to which the selected digital output unit is Unit Tag connected.
Page 54
3.4.2.4. Digital I/O unit Digital input / output unit (product number: EX600-DMF) • IO unit information (digital input/output unit) Description Content Displays the PID of Wireless Base/Remote to which the selected digital input/output unit is connected. Displays the tag of Wireless Base/Remote to which the selected digital input/output unit is Unit Tag connected.
Page 55
3.4.2.5. Analogue input unit Example of analogue input unit (product number: EX600-AXA) IO unit information Status display: No alarm: (OK) Alarm generated: (Details of error) Input/output value of the channel : Refer to 8.Error Code List on page for details of errors. •...
Page 56
3.4.2.6. Analogue output unit Example of analogue output unit (product number: EX600-AYA) IO unit information Status display: No alarm: (OK) Alarm generated: (Details of error) : Refer to 8.Error Code List on page Input/output value of the channel for details of errors. •...
Page 57
3.4.2.7. Analogue I/O unit Example of analogue output unit (product number: EX600-AMB) IO unit information Status display: No alarm: (OK) Alarm generated: (Details of error) : Refer to 8. Error Code List on page Input/output value of the channel for details of errors. •...
4. Setting Function There are functions which can be set more easily by using the I/O configurator for NFC for setting. •Edit TAG (page 57) •Software Control(page 57) •Forced output (page 60) •Export of setting (page 64) •Import of setting (page 66) •Reading of the initial value (page 67) •Initialize the product (page 68) 4.1.
Page 59
Hold/Clear setting procedure (1) Details of the output unit information. (Refer to Description (pate 15, 31) to show the detailed information.) Displayed when Software Control is selected. (2) The window for Unit HOLD/CLR/SET setting appears by clicking the Edit button. From the left Bit0,1,2,3,4,5,6,7 -58-...
Page 60
(3) Upper case letters are used to express the current status of Clear/Hold. The Settable values are C (CLEAR), H (HOLD) or S (SET). Enter 8 characters. When the required values have been entered, click the "Save all" button to store the data. : When CLEAR and HOLD is set for HOLD/CLR/SET, the window below will be displayed.
4.3. Forced output 4.3.1. Forced output conditions The I/O configurator for NFC can directly command the Wireless Base/Remote. Operating conditions for Forced output. [Forced output from the Wireless Base] [Forced output from the Wireless Remote] Forced output Login from the Administrator mode. Login from the Administrator mode.
Page 62
The IO Detail window is displayed. Then, select the Bit (B0 to B7) to be forced output and set to 1. The set value is output by clicking the Enforce button at the bottom of the window. The power supply for output is necessary to activate the output equipment for forced output mode.
Page 63
•Forced output (analogue unit) The window for the forced output for analogue unit is displayed. For forced output for the analogue unit, enter the values according to the analogue range (analogue range can be selected by the I/O configurator for WEB). Enter the values.
4.3.3. Forced output release procedure First, check the box for Enforce ON. Then Click Yes. Click Yes on the following window. Forced output mode is released. Finally. click the Refresh button to update the information in the window. Forced output can also be released by turning off the power supply.
4.4. Export Settings The Export settings tab enables the setting of the unit connected with current NFC reader/writer to be saved to a PC in the format of ".smc". The Import enables the unit setting to be reflected in the other unit. Refer to the table below for settings which can be exported.
Page 66
•Export/import setting Base Remote Item (EX600-WEN#) (EX600-WPN#) (EX600-WSV#) ○ ○ ○ Hold/Clear (unit) ○ ○ ○ Occupied points for the module input ○ ○ ○ Occupied points for the module output Base setting/ Occupied points for the valve manifold ○...
4.5. Import Settings The Import settings tab enables the set file in the format of ".smc" which is save in the PC to be read, and the content of the unit connected with the NFC reader/writer can be changed to the content of the set file. This function is applicable only between the same type of unit (between Bases, or between Remotes) : Refer to 4.4.
4.6. Reading of the initial value Click the "Read factory data" button to initialize or check the parameters in the window currently opened by the setting tab (excluding Remote unit registration and pairing setting). In order to reflect the setting, turn off the power and on again or reset when the power is on.
4.7. Initialize Perform Product initialization of the Base setting or Remote setting to initialize the product. : After executing the function, this function saves and reflects the setting, and updates the information in the window. The operation is not irreversible. -68- No.EX※※-OMV0017-C...
Page 70
Some values set by the I/O configurator (WEB) are included in the initialized items. Refer to the table below for the set items to be initialized. •Initialized items (I/O Configurator (NFC version)) Base Remote Initialized items (EX600-WEN#) (EX600-WPN#) (EX600-WSV#) ○ ○ ○...
5. Pairing of wireless unit 5.1. Pairing procedure of wireless unit : Login to the Administrator mode to change to pairing mode. Refer to 3.1.1 Login to administrator mode (page 13). (1) Change the mode of the Wireless Remote unit to Pairing mode. (1-1) Change the pairing setting of the Wireless Remote unit to "Pairing enable".
Page 72
(2) Change the mode of the Wireless Base unit to Pairing mode. (2-1) Change the pairing setting of the Remote unit registration of the Wireless Base unit to "Pairing enable". (2-2) Reflect the change by clicking Reset module or by re-supplying power. (2-3) Update the contents on the screen by clicking Refresh.
Page 73
(3) Select the wireless channel (3-1) Register the required wireless channel by registering the Remote unit to the Wireless Base unit. Select the wireless channel. (3-2) Move it from the Free Remotes box to Registered Remotes box. (Registration is not complete at this point. The status of the Wireless Remote unit will be shown as "Waiting for registration".) Selected wireless channel is displayed.
Page 74
(4) Determination of the registered information (4-1) Press Save reg-info to register the Wireless Remote unit to the Wireless Base. (4-2) Click Refresh to confirm that the setting has been reflected. (When registration has been completed correctly, the status of the selected Wireless Remote unit will change from "Waiting for registration"...
Page 75
(5) Change of operation mode of the Wireless Base unit (5-1) Change the pairing setting on the Remote unit registration screen of the Wireless Base unit to "Pairing disable". (5-2) Reflect the change by clicking Reset module or by re-supplying power. Now, the registration procedure for the Wireless Base unit and the Wireless Remote unit are complete.
5.2. Registration of dummy Remote (1) Change of operation mode of the Wireless Base unit (1-1) Change the pairing setting of the Remote unit registration of the Wireless Base unit to "Pairing enable". (1-2) Reflect the change by clicking Reset module or by re-supplying power. (1-3) Update the contents on the screen by clicking Refresh.
6. Wireless system configuration example The Wireless system configuration method is shown below. Perform the preparation according to section 2. Preparation before use (page 7) before configuring the wireless system. The example below is based on the Step 2 Setting/installation of the wireless unit of 6.1 Flow chart for using the wireless system (page 76) to explaining the Example 1 of 6.2 System Configuration example (page 77).
Wireless Base module construction Input data: [Unit 1] Digital input unit (EX600-DXD): 2 bytes occupied Output data: [Unit 0] Digital output unit (EX600-DYB): 1 byte occupied [Unit 2] Wireless Base unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DYB...
Page 79
Unit name Module name Unit name System diagnosis 1 B (Unit 0) byte0 System diagnosis 2 byte1 EX600-WEN# (Unit 2) Wireless Base module Valve output: 16 points System diagnosis 3 byte2 System diagnosis 4 Reserved byte3 Wireless Remote connection information ...
6.3. Preparation STEP 1 Start the I/O Configurator (NFC version) STEP 2 Login to Administrator mode STEP 1 Start the I/O Configurator (NFC version) (1) Start up the I/O Configurator (NFC) and connect the NFC reader/writer to the PC. "R/W detected" will turn on in green when the PC detects the NFC reader/writer.
Page 81
(2) Hold the NFC reader/writer over the Wireless Remote (1). Wireless Base Wireless Remote ② Wireless Remote ① (3) Click the "Refresh" button to update the information in the Information tab window of the Wireless Remote (1). Update of the Information tab window -80- No.EX※※-OMV0017-C...
Page 82
STEP 2 Login from the Administrator mode. (1) Click the radio button for Administrator mode. (2) Enter the password in the Password check window. : The default password at the time of shipment from the factory is admin. (3) When the following password input window is displayed, click Confirm. "Password checking passed."...
Page 83
(4) Confirm that the radio button "Administrator mode" is checked during the login state. : The mode is automatically changed to the monitor mode unless a mouse operation is made within 300 seconds in Administrator mode. Window to complete login -82- No.EX※※-OMV0017-C...
6.4. (1) Input and output size of the Wireless Remote STEP 3 Change of parameter setting (Wireless Remote (1)) STEP 4 Change to pairing mode (Wireless Remote (1)) STEP 5 Change of parameter setting (Wireless Remote (2)) STEP 6 Change to pairing mode (Wireless Remote (2)) STEP 3 Change of parameter setting (Wireless Remote (1)) (1) Click the Properties tab to move to the Remote setting window.
Page 85
(3) Change the parameter setting of the Wireless Remote(1) to the values in the table for parameter setting. (4) Click the "Save all" button to save the set values in the Wireless Remote (1). Table for the change of parameter setting (Wireless Remote (1)) Setting items Set value Hold/Clear (unit)
Page 86
(5) The parameter setting of the Wireless Remote(1) is complete. Remote setting window after setting (Wireless Remote (1)) -85- No.EX※※-OMV0017-C...
Page 87
STEP 4 Change to pairing mode (Wireless Remote (1)) (1) Click the radio button for Pairing setting to move to the pairing setting window. From the Remote setting window to Pairing setting (Wireless Remote (1)) (2) Click the "Refresh" button to update the information in the Pairing setting window. Pairing setting window (Wireless Remote (1)) -86- No.EX※※-OMV0017-C...
Page 88
(3) Click the radio button for Pairing mode. (4) Click Yes to change to the pairing mode. : Remote reset is requested when the mode is changed to pairing mode. The Remote cannot be reset when the power supply is not connected.
Page 89
STEP 5 Change of parameter setting (Wireless Remote (2)) (1) Hold the NFC reader/writer over the Wireless Remote (2). Wireless Base Wireless Remote ② Wireless Remote ① (2) Click the "Refresh" button to update the window of the Wireless Remote (2). (3) Click the radio button for Remote setting to move to the Remote setting window.
Page 90
(4) Click the "Refresh" button to update the information in the Remote setting window for the Remote unit. (5) Change the parameter setting of the Wireless Remote(2) to the values in the table for parameter setting. (6) Click the "Save all" button to save the set values in the Wireless Remote (2). Table for the change of parameter setting (Wireless Remote (2)) Setting items Set value...
Page 91
(6) The parameter setting of the Wireless Remote (2) is complete. Remote setting window after setting (Wireless Remote (2)) -90- No.EX※※-OMV0017-C...
Page 92
STEP 6 Change to pairing mode (Wireless Remote (2)) (1) Click the radio button for Pairing setting to move to the pairing setting window. From the Remote setting window to Pairing setting (Wireless Remote (2)) -91- No.EX※※-OMV0017-C...
Page 93
(2) Click the radio button for Pairing mode. (3) Click Yes to change to pairing mode. : Remote reset is requested when the mode is changed to pairing mode. The Remote cannot be reset when Power off. (4) Confirm that the radio button "Pairing mode" is checked. (2) (4) Pairing check window (Wireless Remote (2)) -92-...
6.5. Set the number of occupied I/O points for the module and each parameter of the (2) "Wireless Base" STEP 7 Change of parameter setting STEP7 Change of parameter setting (1) Hold the NFC reader/writer over the Wireless Base. -93- No.EX※※-OMV0017-C...
Page 95
(2) Click the "Refresh" button to update the window of the Wireless Base. (3) Click the radio button for the Base setting to move to the Base setting window. Moves to Base setting Caution: The Power supply check window appears when Power off. Base setting can be changed when Power off.
Page 96
(4) Click the "Refresh" button to update the information in the Base setting window. (5) Change the parameter setting of the Wireless Base to the values in the table for parameter setting. (6) Click the "Save all" button to save the set values in the Wireless Base. Values for parameter setting Setting items: Set value...
Page 97
(7) The parameter setting of the Wireless Base is complete. Base setting window after setting -96- No.EX※※-OMV0017-C...
6.6. (3) Set the "Wireless Base" system STEP 8 Change of system setting STEP8 Change of system setting (1) Click the radio button for System setting to move to the system setting window. (2) Click the Refresh button to update the information in the System setting window. Base setting window to System setting -97- No.EX※※-OMV0017-C...
Page 99
(3) Change the system settings of the Wireless Base to the values in the table for system setting. (4) Click the "Save all" button to save the set values in the Wireless Base. Values for system setting Setting items Set value I/O mapping Automatic assignment System input size...
Page 100
(5) The system setting of the Wireless Base is complete. System unit setting window after setting -99- No.EX※※-OMV0017-C...
6.7. (7) Ethernet setting for the Wireless Base Change of Ethernet setting STEP 9 STEP9 Change of Ethernet setting (1) Click the radio button for Ethernet setting to move to the Ethernet setting window. (2) Click the Refresh button to update the information in the Ethernet setting window. System setting window to Ethernet setting -100- No.EX※※-OMV0017-C...
Page 102
(3) Change the Ethernet setting of the Wireless Base to the Ethernet setting table. : Set the IP address based on the operating network environment. Set the IP address so that the address is not duplicated with other Ehternet equipment. (4) Click the "Save all"...
Page 103
(5) The Ethernet setting of the Wireless Base is complete. Ethernet setting window after setting -102- No.EX※※-OMV0017-C...
6.8. (4) Registration of Wireless Remote to the Wireless Base (pairing) STEP 10 Move the Wireless Base and Remote to Pairing mode STEP 11 Select the Wireless Remote to be registered STEP 12 The Wireless Base gives a command to register the Wireless Remote STEP 13 Check the wireless connection STEP 10 Move the Wireless Base and Remote to Pairing mode...
Page 105
(4) Click the Refresh button to update the information in the setting tab window. (5) Check that the Power on button in the power supply monitor is green. (6) Click the radio button for Remote registration to move to the Remote unit registration window. From the Ethernet setting window to Remote unit registration -104- No.EX※※-OMV0017-C...
Page 106
(7) Click the "Refresh" button to update the information in the Remote registration window. (8) Click the radio button for Pairing mode. (9) Click Yes to change to pairing mode. (10) Click the "Refresh" button to move to Pairing mode. (10) Remote unit registration window (move the Wireless Base to the Pairing mode) (11) The Pairing status of the Wireless Base can be checked by the status indication LED: W-NS.
Page 107
(12) Click the Refresh button to update the information in the setting tab window. Click OK in the Pairing mode check window. (12) Update the Remote unit registration window (13) Confirm that the Wireless Remote is displayed in the Free Remotes area. (13) Remote unit registration window (check Free Remotes) -106-...
Page 108
< Caution > •When the Wireless Base/Remote is moved to pairing mode, the W-SS LED flashes red and green in turn. W-SS indicates the received power level of the connected Wireless Remote. When the Wireless Remote and Base are connected, the LED turns on and flashes (1Hz/2Hz). Red flashing LED indicates the Wireless Base is not identified.
Page 109
STEP 11 Select the Wireless Remote to be registered (1) Select the Wireless Remote to be registered (1) (PID:07914009) (2) Select the wireless channel (001) of the Wireless Remote(1) to be registered. (3) Click the "▲". Remote unit registration window (wireless channel: 001 is selected) -108- No.EX※※-OMV0017-C...
Page 110
(4) Select the Wireless Remote to be registered (2) (PID: 07914002) (5) Select the wireless channel (002) of the Wireless Remote(2) to be registered. (6) Click the "▲". Remote unit registration window (wireless channel: 002 is selected) (7) Make sure that the registration status is Registered Wait. Remote unit registration window (check the registration status) -109- No.EX※※-OMV0017-C...
Page 111
STEP 12 Wireless Base gives a command for registration (1) Click the "Save reg. info". button for the Wireless Base to send a command for registration. (2) Make sure that the registration status of the Wireless Remote is Registered. : The pairing mode of the registered Wireless Remote is automatically released and the Wireless Remote is reset. Pairing setting becomes unavailable.
Page 112
< How to delete the Wireless Remote for which registration failed > Perform pairing for the Wireless Remote which failed registration. In order to register the Wireless Remote again, it is necessary to delete the Wireless Remote which failed registration. The procedure to delete is as follows:. (1) Select the Wireless Remote for which registration failed.
Page 113
STEP 13 Check the wireless connection (1) Click the Normal mode button for Pairing:. (2) Click Yes to change to pairing mode. (3) Click the "Reset" button to release the pairing mode. Remote unit registration window (release the pairing mode of the Wireless Base) (4) Confirm that wireless communication is established on the status indication LED of the Wireless Base.
Page 114
(5) Confirm that wireless communication is established on the status indication LED of the Wireless Remote. •LED: W-NS turns on green when all Wireless Bases are connected. (6) Click the "Refresh" button to update the information in the Remote registration window. (7) Select the information tab to check that the Wireless Remotes are connected.
Page 115
(8) Click the Refresh button to update the information tab window. (9) Confirm that the registered Wireless Remote is displayed in the System configuration. Information tab window (to check the connection of the Wireless Remote) Configuration of the wireless system is complete. -114- No.EX※※-OMV0017-C...
6.9. Download the configuration file For connecting to the PLC and Ethernet, download the configuration file for the wireless system from the SMC website < Download procedure > On the SMC website (https://www.smcworld.com/), select the Documents/Download and select the Instruction Manuals.
Page 117
Select the Fieldbus protocol. (Example: EtherNet/IP™ compatible) Scroll down the page of the Fieldbus System Serial Transmission System and select the Configuration File for SMC Wireless System EtherNet/IP Compatible. Downloading of the configuration file will begin. -116- No.EX※※-OMV0017-C...
7. Wireless system parameter list •Wireless Base unit (EX600-WEN#) setting parameters Setting when Classification Parameter name Set value Default Note Power off Setting of output operation status Hold/Clear Clear/Hold/Software control CLEAR Available when the Fieldbus (unit) communication is disconnected. 0 to 128 points...
Page 119
•Wireless Base unit (EX600-WPN#) setting parameters Setting when Classification Parameter name Set value Default Note Power off Setting of output operation status Hold/Clear Clear/Hold/Software control CLEAR Available when the Fieldbus (unit) communication is disconnected. 0 to 128 points (0 to 16 bytes) 128 points/ b) Input size Available...
Page 120
•Common parameter of Wireless Base unit and the Wireless Remote unit Setting when Classification Parameter name Set value Default Note Power off Product No. Letters which can be input are (EX600-WEN#) half-width characters (alphabets, Information Max. 15 letters Available (EX600-WPN#) numbers, symbols) that (EX600-WSV#) correspond to ASCII code. -119-...
8. Error Codes Error Message Content Short-circuit detection of load Short circuit of the power supply or load is detected. Detection of unconnected load The valve manifold/output unit load is not connected. Contact operation exceeded the The upper limit of the unit operation cycle has been exceeded. upper limit Exceed the upper limit of the range The upper limit of analogue input range has been exceeded.
9. Troubleshooting Problem Problem Possible causes Investigation and countermeasures 1: Adjust the NFC reader/writer so that it is positioned at the centre of the NFC antenna (circled part). 1. The NFC reader/writer has The Wireless Base/ 2-1: Remove the NFC reader/writer from the moved away from the Remote unit information USB terminal of the PC once and...
Page 123
Problem Problem Possible causes Investigation and countermeasures 1. Connected with a higher Not possible to change to 1. Disconnect the unit from the higher unit. unit. forced output mode. 2. Login from the Administrator mo de. 2. Mode is Monitor mode. The Wireless Remote follows the input/output The Wireless Remote size when it was registered to the Wireless...
First edition EX600-WSV※ EX600-WPN※ Version for EX600-WPN※ 2.1.0 EX600-WSV※ EX600-WEN※ Common version for EX600-WEN※ and EX600-WPN※ EX600-WPN※ 2.2.0 Advanced Card Systems Ltd. reader / writer has been added to verified EX600-WSV※ NFC reader / writer. EX600-WEN※ Added "Remote control" as a mode of setting IP address.
Page 125
Revision history A: Contents revised in several places. [August 2018] B: Contents are added. [August 2018] C: Contents revised in several places. [November 2019] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
Need help?
Do you have a question about the EX600-WEN and is the answer not in the manual?
Questions and answers