SMC Networks EXW1-BMJA Series Operating Manual

I/o configurator
Hide thumbs Also See for EXW1-BMJA Series:

Advertisement

Quick Links

Wireless Base
Wireless Remote EXW1-RDY#M5C
PRODUCT NAME
I/O Configurator (NFC version)
Model / Series / Product Number
EXW1-BMJA#, EXW1-BDNAC
EXW1-BENAC1, EXW1-BPNAC1
EXW1-BECAC
EX600-WPN#
EX600-WEN#
EXW1-RDX#G4C#
EXW1-RDY#G4C#
EXW1-RDM#G3C#
EXW1-RDX#E4##
EXW1-RDY#E4##
EXW1-RDM#E3##
EXW1-RAXZA2C
EXW1-RL#PA#C
EX600-WSV#
No.EX##-OMV0017-J

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EXW1-BMJA Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SMC Networks EXW1-BMJA Series

  • Page 1 No.EX##-OMV0017-J PRODUCT NAME I/O Configurator (NFC version) Model / Series / Product Number Wireless Base EXW1-BMJA#, EXW1-BDNAC EXW1-BENAC1, EXW1-BPNAC1 EXW1-BECAC EX600-WPN# EX600-WEN# Wireless Remote EXW1-RDY#M5C EXW1-RDX#G4C# EXW1-RDY#G4C# EXW1-RDM#G3C# EXW1-RDX#E4## EXW1-RDY#E4## EXW1-RDM#E3## EXW1-RAXZA2C EXW1-RL#PA#C EX600-WSV#...
  • Page 2: Table Of Contents

    Contents Introduction ......................3 License Agreement ........................3 About the I/O Configurator (NFC version) ................... 4 SMC wireless system (system configuration) ................6 System compatibility ........................7 About this manual ........................12 Basic operations with the I/O Configurator (NFC version) ........13 Download the I/O Configurator (NFC version) ................
  • Page 3 Wireless system parameter list................123 Troubleshooting ....................191 Specifications / technical information / supplementary information ..... 193 Terminology ..........................193 No.EX##-OMV0017-J...
  • Page 4: Introduction

    1. Introduction License Agreement SMC Corporation (hereinafter referred to as "SMC") hereby grants the user (regardless of whether the user is a corporation or an individual) a license to use this software "I/O Configurator" (hereinafter referred to as "Software") according to this License agreement (hereinafter referred to as "Agreement") under the articles listed below.
  • Page 5: About The I/O Configurator (Nfc Version)

    About the I/O Configurator (NFC version) With the I/O Configurator (NFC version), the status of a wireless system can be checked and all parameters of a wireless unit can be set from a PC using an NFC reader / writer. The status can be checked without logging in (Monitor mode).
  • Page 6 The following products support the I/O Configurator (NFC version). [ Wireless Base ] EXW1-BMJA# EXW1-BDNAC EXW1-BECAC EXW1-BENAC1 EXW1-BPNAC1 EX600-WEN# (manifold type) EX600-WPN# (manifold type) [ Wireless Remote ] EXW1-RDY#M5C EXW1-RDX#G4C# EXW1-RDY#G4C# EXW1-RDM#G3C# EXW1-RDX#E4## EXW1-RDY#E4## EXW1-RDM#E3## EXW1-RAXZA2C EXW1-RL#PA#C EX600-WSV# (manifold type) To use a wireless system, it is necessary to "pair"...
  • Page 7: Smc Wireless System (System Configuration)

    SMC wireless system (system configuration) PLC compatible with EX600-W and EXW1 series communication protocols. <Base> EX600-W Series EXW1 series For settings and other information, refer to the operation manual for EX600-WEN/WPN*. <Remote> EXW1 series EX600-W Series For settings and other information, refer to the operation manuals for EX600-WSV* and the connected digital and analog units.
  • Page 8: System Compatibility

    System compatibility Mixed use with EX600-W Series Although it is possible to use with EX600-W series, the operating conditions must comply with the specifications of the existing wireless system. Note that the following functions may be restricted: •Communication distance The maximum communication distance will vary depending upon the system configuration. Please see the details in the table on the next page.
  • Page 9: Wireless Remote

    Refer to the system configuration example below. For details, please refer to the instruction manual for each product. System configuration example Applicable function Power Communication Wireless Wireless Transmission distance Protocol F.C.S. Base Remote Level setting Up to 100 m 〇 〇...
  • Page 10 〇System configuration 2 Wireless Base : EXW1-BENAC1 Wireless Remote: EXW1 series, EX600-W series <Wireless Base> <Wireless Remote> EX600-W series EXW1 series No.EX##-OMV0017-J...
  • Page 11 〇System configuration 3 Wireless Base : EXW1-BENAC1 Wireless Remote: EX600-W Series <Wireless Base> <Wireless Remote> EX600-W Series -10- No.EX##-OMV0017-J...
  • Page 12 〇System configuration 4 Wireless Base: EX600-W Series Wireless Remote: EXW1 Series <Wireless Base> EX600-W series <Wireless Remote> EXW1-RL* EXW1-RD* 〇System configuration 5 Wireless Base: EX600-W Series Wireless Remote: EXW1 Series, EX600-W Series <Wireless Base> EX600-W Series <Wireless Remote> EXW1 Series EX600-W Series -11- No.EX##-OMV0017-J...
  • Page 13: About This Manual

    〇 System configuration 6 Wireless Base: EX600-W series Wireless Remote: EX600-W series For system configurations of EX600-W series, refer to the operation manual of the product in use for the further details. About this manual This manual can be used with the I/O Configurator (NFC version) ver. 2.15.0. -12- No.EX##-OMV0017-J...
  • Page 14: Basic Operations With The I/O Configurator (Nfc Version)

    2. Basic operations with the I/O Configurator (NFC version) Download the I/O Configurator (NFC version) (1) On the SMC website (https://www.smcworld.com), select [Product Information] and click [Operation Manuals/Configuration Files]. (2) Select the Fieldbus System Serial Transmission System. -13- No.EX##-OMV0017-J...
  • Page 15 (3) Select the protocol supported by the product (Example: EtherNet/IP compatible). (4) Scroll down the page of the Fieldbus Serial Transmission System and click the Configuration File for the I/O Configurator (NFC version). The download will begin. ##.0 Older versions of the I/O Configurator (NFC version) can be downloaded as well as the latest version. Download the version which is suitable for your device.
  • Page 16: Start The I/O Configurator (Nfc Version)

    Start the I/O Configurator (NFC version) (1) Extract the contents of the downloaded ZIP file into an appropriate folder on your computer. (2) Double-click "IOConfigurator.exe". The I/O Configurator (NFC version) will start up. To move IOConfigurator.exe to the desktop or another location, either move the entire the I/O Configurator folder, or create a shortcut for IOConfigurator.exe and use the program through it.
  • Page 17: Basic Characteristics

    - Basic characteristics Item Explanation Click the [?] button to see the revision details of the I/O Configurator (NFC Version). Version information button The Refresh button updates the Wireless Base/Remote module information displayed on the application window. The information on the window is not updated automatically. Refresh button Always click the Refresh button when moving to a tab or after parameter settings.
  • Page 18: Monitor Mode And Administrator Mode

    Monitor mode and Administrator mode The I/O Configurator (NFC version) has two modes: 'Monitor mode' and 'Administrator mode', depending on the functions available. (a) Monitor mode Wireless unit information or I/O map and parameter settings can be read. Parameters cannot be set. The Forced output function cannot be used.
  • Page 19 - Login to administrator mode A password is necessary to log in to Administrator mode. Any password can be set. To prevent unauthorized use, it is advisable to change the default password when the I/O Configurator is first used. (1) Select the [Administrator mode] radio button. (2) Type a password while holding the NFC reader / writer near the NFC antenna approach area of the wireless unit and click the [Confirm] button.
  • Page 20 - Troubleshooting Read error: Confirm that the NFC reader / writer is connected to the PC. Confirm that the NFC reader / writer is held near the NFC antenna approach area. If frozen: Remove the NFC reader / writer from the PC and reconnect it. After taking the above actions, click the [Refresh] button.
  • Page 21: Basic Operational Flow For Settings And Monitoring

    Basic operational flow for settings and monitoring To change settings, switch to Administrator mode to operate the I/O Configurator. In Administrator mode, a timeout occurs after 300 seconds of inactivity and the application returns to Monitor mode. A timeout countdown is displayed to the right of the "Administrator mode" label. - The NFC communication is not accessed all the time.
  • Page 22  Operational flow when changing settings A rough operational flow during setting changing operations is shown below (operations performed in Administrator mode). (1) Select the tab that you wish to check (2) Display the setting item that you wish to check (3) Click [Refresh] (4) Check the present settings and values (5) Change the necessary item and value settings...
  • Page 23: Explanation Of Screens

    Explanation of screens The tabs available on the I/O Configurator (NFC version) consist of the [Information], [I/O monitor], [Properties], and [Parameter] tabs. On an EXW1-series Base unit, [Event] and [Wireless] tabs are displayed to the right of the [Properties] tab. An outline of each tab is explained below.
  • Page 24 ⚫ I/O monitor tab The wireless unit's I/O data can be monitored. The display can be switched between input and output displays by clicking the tabs at the top of the status display area. With a Base unit (EXW1-BMJA#) that supports CC-Link, the display can be switched between Bit area and Word area.
  • Page 25 ⚫ Properties tab Settings of a connected wireless unit can be changed in the Properties tab. The area displayed for making settings can be changed by selecting a radio button in the "Control panel". -24- No.EX##-OMV0017-J...
  • Page 26 ⚫ Event tab Displayed on an EXW1-series Base unit, this tab makes it possible to check the event information (errors, etc.) of the Wireless Base or Wireless Remotes. ⚫ Wireless tab Displayed on an EXW1-series Base unit, this tab makes it possible to check wireless log data. - Not displayed for a EXW1 series Base unit.
  • Page 27 ●Parameter tab This tab makes it possible to check and change the parameters of the Wireless Base or Wireless Remotes. -26- No.EX##-OMV0017-J...
  • Page 28: Setting Of The Wireless Unit System

    3. Setting of the wireless unit system This section describes the installation of the SMC wireless system (Base and Remote) so that it can be controlled by an upper-level controller. Grayed out items do not use the I/O Configurator. Refer to the operation manual for each product.
  • Page 29: Reading And Obtaining Device Information

    Reading and obtaining device information Start up the I/O Configurator and initiate NFC read-in with the Information tab to obtain information for each unit and the system. The parameters displayed depend on the unit. Unit information Description System configuration ● Unit information area The unit information area indicates the module information.
  • Page 30: Entry Of Individual Identification (Edit Tag)

    ● System configuration area System configuration shows the configuration information of the Wireless Base/Remote modules. "Error" appears to the right of a unit name when an error occurs. Connected I/O units can be checked by double-clicking on the name of a displayed wireless unit or clicking on the "▶"...
  • Page 31: Remote Setting

    Remote setting Set the parameters of a Remote unit. - I/O points and parameter setting - The setting will be applied when the Remote is turned on (or reset). ● I/O points and parameter setting Set the occupied I/O points and parameters for the module in [Remote setting]. Settable parameters depend on the unit being set (refer to "5.3 Properties tab"...
  • Page 32 Remote unit setting items (example using compact wireless unit EXW1-RDX#E4## / EXW1-RDY#E4## / EXW1-RDM#E3##) Parameter name Set value Initial value Input size* 16 points (16 bits) 16 points (16 bits) Output size (includes valves)* 16 points (16 bits) 16 points (16 bits) Wireless signal Active / Idle Active...
  • Page 33: Base Setting

    Base setting Make the Base unit settings. Set the communication environment using the PLC, make unit settings, etc. - Communication environment with PLC ([Ethernet setting], [CC-Link Setting] , [DeviceNet Setting] , [EtherCAT Setting]) - I/O points and parameter setting - System setting - OPC UA setting ●...
  • Page 34 Ethernet setting items (example using manifold-type wireless unit EX600-WEN) Parameter name Set value Initial value MAC address Manual / DHCP / Remote Control IP address type Manual IP address Enter value 192.168.0.1 Auto MDI/MDI-X Auto / MDI / MDIX Auto Duplex Full Duplex / Half Duplex Full Duplex...
  • Page 35 ● DeviceNet setting Make the DeviceNet settings when using a Base unit that supports DeviceNet. The parameters below can be set (refer to "5.3 Properties tab"). DeviceNet setting items (example using compact wireless unit EXW1-BDNAC) Parameter name Set value Initial value MAC ID 0 to 63, PGM 125/250/500kbps, Auto, PGM...
  • Page 36 ● EtherCAT setting Make the EtherCAT settings when using a Base unit that supports EtherCAT. The parameters below can be set (refer to "5.3 Properties tab"). EtherCAT setting items (example using compact wireless unit EXW1-BECAC) Parameter name Set value Initial value Custom setting Enable / Disable Disable...
  • Page 37 ● I/O points and parameter setting Set the occupied I/O points and parameters for the module using [Base setting]. Base unit setting screen (example using EX600-WEN) ¥ The parameters below can be set (refer to "5.3 Properties tab"). Base unit setting items (example using manifold-type wireless unit EX600-WEN# / EX600-WPN#) Parameter name Set value Initial value...
  • Page 38 ● System setting Change the parameter settings as required. System setting screen (example using EXW1-BMJA#) ¥ ¥ The parameters below can be set. Settable parameters depend on the unit being set (refer to "5.3 Properties tab" for details). System setting items (example using compact Wireless Base EXW1-BMJA#) Parameter Set value Initial value...
  • Page 39 System setting items (example using compact Wireless Base EXW1-BECAC) Parameter Set value Initial value I/O mapping Auto Auto Diagnostic allocation None/Simple/ Advanced Advanced Max. Remote units 15 /31/63 Remotes 15 Remotes 100/200/500/1,000 msec Wireless communication 500 msec timeout /2,000/5,000 msec Power Transmission Level High/Middle/Low High...
  • Page 40 System setting items (example using compact Wireless Base EXW1-BDNAC) Parameter Set value Initial value I/O mapping Manual / Auto Manual System input size 16, 128,256,512,768,1024,1280,2048,3088,3968, 1280 points/160 byte 4096 points 2, 16,32,64,96,128,160,256,386,496,512bytes System output size 16, 128,256,512,768,1024,1280,2048,3088,3968, 1280 points/160 byte 4096 points 2, 16,32,64,96,128,160,256,386,496,512bytes Diagnostic allocation...
  • Page 41 ● OPC UA setting Change the parameter settings as required. System setting screen (example using EXW1-BPNAC1) ¥ ¥ The parameters below can be set. Settable parameters depend on the unit being set (refer to "5.3 Properties tab" for details). OPC UA setting items (example using compact Wireless Base Parameter Set value Initial value...
  • Page 42 ● Frequency channel select function (F.C.S.) With a EXW1 series Base unit, the frequency channel can be selected. Only protocol V.2.0 is supported. Specify protocol V.2.0 in [System setting]. * The number of selectable frequency channels varies depending on the country in use. Refer to the operation manual for the product in use.
  • Page 43 Set using the [Frequency Channel Select Window]. Item Description Read button Retrieves the current channel selection configuration. The W-LAN indicators make it possible to select frequency channels corresponding to W-LAN Channel W-LAN channel at one time. (2) indicators * In the example above, W-LAN Channel: CH.10 is selected. The W-CH indicators make it possible to select frequencies for each CH.
  • Page 44: Pairing

    Pairing Pairing procedure 3.5.1 Pairing is required for communication between a Base and Remote. A Base is paired with a Remote after they are switched to pairing mode. Pairing and registration between a Base and Remote enables wireless communication.  Operational flow during pairing Switch the Remote to pairing mode * The EXW1-RD# is set to pairing mode by factory default.
  • Page 45 (1) Switch the Remote to pairing mode Connect to the Remote using NFC, select the (a) [Properties] tab and then click (b) [Refresh]. Select (d) [Pairing mode] from (c) [Pairing setting] on the (a) [Properties] tab and then click (e) [Reset module].
  • Page 46 (2) Switch the Base to pairing mode Connect to the Base using NFC, select the (a) [Properties] tab and then click (b) [Refresh]. Select (d) [Pairing mode] from (c) [Remote registration] on the (a) [Properties] tab and then click (e) [Reset module].
  • Page 47 (3) Pair and register the Base and Remote (a) Clicking [Refresh] causes Remotes in pairing mode to be listed in the Free Remotes area. (b) Select the Remote that is to be registered, Change the Input size and Output size settings as required. (c) specify a wireless channel and then (d) click ▲...
  • Page 48 * Input size / Output size setting In protocol V.2.0, it is possible to configure remotes (such as EXW1-RL*PA*C) with variable input/output occupied bytes.* Refer to the "I/O Map" section in the Operation Manual for each product for the range of Input/Output size to be set. The Remote that is to be registered on the specified wireless channel moves to the Registered Remotes area.
  • Page 49 Click (a) [Reset module] and (b) [Refresh] and check that the registration status changes to Registered. Base setting screen ¥ ¥ * The example below shows two Remote modules registered on channel 1 and channel 2. Base setting screen ¥ ¥...
  • Page 50 (4) Disable the pairing mode of the Base (Normal mode) Connect to the Base using NFC, (a) Select [Normal mode] (b) Click [Reset module] to registered Base. (c) Check connection with registered Remotes. ¥ ¥ -49- No.EX##-OMV0017-J...
  • Page 51: Unpairing Procedure

    Unpairing procedure 3.5.2 Pairing between a Base and Remote can be deactivated. When you wish to reconfigure the wireless system, such as changing the I/O sizes of a registered Remote, pairing needs to be deactivated and registered again. ○Operational flow during unpairing (1) Switch the Base to pairing mode (2) Remove pairing between a Base and Remote (3) Disable the Pairing mode of the Base (Normal mode)
  • Page 52 (2) Removing the pairing between the Base and Remote Pairing between the Base and Remote will be removed. Click [Refresh]. Select the Remote that you wish to unpair from the registered Remotes and click ▼, which in turn causes the selected Remote to move to the Free Remotes area. Clicking [Save reg.
  • Page 53: Dummy Remote

    Dummy Remote Configure dummy Remotes to reserve memory space in I/O map and so that Remotes to be added and registered later, without changes to mapping, even after the system has been configured. Register dummy Remotes using the Base. ¥ ¥...
  • Page 54: Software Control

    Software Control "HOLD/CLR setting (unit): Software control" of "Base/Remote setting", the output operation for when the Ethernet communication is disconnected, can be selected for valve output or output unit independently, in 1- point units, using "CLEAR", "HOLD", or "SET". The values for the Hold / Clear for each valve output or output unit are stored in the unit with outputs.
  • Page 55 (3) Upper case letters are used to express the current status of Clear / Hold. The settable values are C (CLEAR), H (HOLD) or S (SET). Enter 8 characters. When the required values have been entered, click the "Save all" to store the data. * When CLEAR or HOLD is set for HOLD/CLR/SET, the window below will be displayed.
  • Page 56: Using A Setting File

    Using a setting file The [Export] button in the Properties tab enables the setting of the connected unit using the current NFC reader / writer to be saved to a PC in the format of ".smc". Importing as explained in the next item enables the unit setting to be reflected in other units.
  • Page 57 ◆ Procedure for importing the settings (1) Click the "Import" button. ¥ (2) Select the required file and click [Open]. Select "Yes" to execute the import of settings. -56- No.EX##-OMV0017-J...
  • Page 58 - Export/import settings (EX600 series) Base Remote Item EX600- EX600- EX600- WEN# WPN# WSV# HOLD/CLR (unit) Input size Output size (includes valves) in which includes a valve density Wireless signal Base settings/Remote settings AD refresh time (sec) Unit address order Power Supply Voltage Monitor (Control/Input) Power Supply Voltage Monitor...
  • Page 59 - Import / Export settings (EXW1 series Base) EXW1- EXW1- EXW1- EXW1- EXW1- Item BMJA# BDNAC BECAC BENAC1 BPNAC1 Remote Normal / pairing modes registration / FCS Setting pairing setting IP address type IP address Subnet Mask Default Gateway Ethernet setting Auto MDI / MDI-X Duplex Speed...
  • Page 60 - Import / Export settings (EXW1 series Remote) EXW1- EXW1- EXW1- Item RDX#E4# RDY#E4# RDM#E3## HOLD/CLR (unit) Input size Output size (includes valves) in which includes a valve density of Remote setting Wireless signal Power Supply Voltage Monitor (Control/Input) Power Supply Voltage Monitor (Output) Output Action of Upper Communication Output action when wireless community to cut off.
  • Page 61: Reading Of Factory Data

    Reading of factory data Click the [Read factory data] button to initialize or check the parameters in the window currently opened in the [Properties] tab (excluding Remote unit registration and pairing setting). In order to reflect the setting, turn off the power and on again or click [Reset module] when the power is on. Turn on the power supply if the power is off.
  • Page 62: 3.10 Initialization Of The Product

    3.10 Initialization of the product To initialize the product, in the [Properties] tab, click [Product initialization] in [Base setting] or [Remote setting]. ¥ ¥ - After executing initialization, this function saves and reflects the setting, and updates the information in the window. The operation is not reversible. Care should be taken. - With an EXW1-RD#, initializing the product results in switching to pairing mode.
  • Page 63 Some values settable by the I/O Configurator (Web version) are included in the initialization items. Refer to the table below for the set items to be initialized. Initialization items (I/O Configurator (NFC version) (EX600 series)) Base Remote Initialized items EX600-WEN# EX600-WPN# EX600-WSV# HOLD / CLR (unit)
  • Page 64: I/O Monitoring

    4. I/O monitoring In the [I/O monitor] tab, the I/O mapping data can be monitored. Input Shows the input mapping information of the wireless unit. ¥ - Input display Display Description ADRS Displays the input map address. Wireless unit channel. W.ch (Wireless channel of the Base is displayed as [- -].
  • Page 65: Output

    Output Shows the output mapping information of the wireless unit. ¥ ¥ - Output display Display Description Forced output mode can be selected by clicking [Enforce ON]. Enforce ON * Refer to "4.4 Forced output" for details on operation. ADRS Displays the output map address.
  • Page 66: Detailed Input / Output Information

    Detailed Input / output information The IO Detail window will open by double-clicking the line of an address of the I/O unit which is connected to the wireless unit. ¥ ¥ Double-click The diagnostic error type is represented by different background colours. The meaning of a background colour can be checked by clicking [>>].
  • Page 67: Forced Output

    Forced output Forced output conditions 4.4.1 The I/O Configurator (NFC version) can directly control the Wireless Base/Remote. Operating conditions for forced output. [Forced output from the Wireless Base] [Forced output from the Wireless Remote] Forced output Login to Administrator mode. Login to Administrator mode.
  • Page 68 The window below appears when the mode is changed to forced output mode. Select the output unit to change to forced output and double-click it. ¥ ¥ Double-click -67- No.EX##-OMV0017-J...
  • Page 69 In the [IO Detail] window, select the bit (B0 to B7) to change to forced output and set to "1". The set value is output by clicking the [Enforce] button at the bottom of the window. The power supply for the output unit is necessary to activate the output equipment for forced output mode. Refer to the Operation Manual for the SMC Wireless System for details of the power supply for output.
  • Page 70 Forced output (analog unit) For forced output for an analog unit, enter the values according to the analog range. The analog range can be selected by the I/O Configurator (Web version). Enter the values. The analog value will be output by clicking the [Enforce] button.
  • Page 71 Exiting forced output mode Remove the check mark in the "Enforce ON" box to exit forced output mode. In the dialog box, to confirm exiting forced output mode, select [Yes]. Continue by clicking [Yes] on the following window. Forced output mode is exited.
  • Page 72: Screen Details Of The I/O Configurator (Nfc Version)

    5. Screen details of the I/O Configurator (NFC version) Information tab The Information tab consists of "Unit information", "System configuration" and "Description". ¥ ¥ Unit information Description System configuration Unit information area 5.1.1 The unit information area indicates the module information. - Unit information display NFC access Display...
  • Page 73: System Configuration Area

    System configuration area 5.1.2 The system configuration area shows the configuration information of the Wireless Base/Remote module. Wireless Base Unit selected Dummy Remotes (reserved) Error indication: any error is shown here Wireless Remote Connected I/O units can be checked by double-clicking on a wireless unit displayed in the system configuration area or clicking on the "▶"...
  • Page 74: Description Area

    Description area 5.1.3 Description of the unit selected in the system configuration area. Information tab, description 5.1.4 Wireless unit (manifold type) 5.1.4.1 1) Communication unit ¥ ¥ -73- No.EX##-OMV0017-J...
  • Page 75: Diagnostic Information

    - Description display (communication unit) Display Description Part No Wireless unit product number. Wireless unit PID. Wireless unit user tag number. The wireless unit status is displayed in 4 bytes as hexadecimal numbers. ◆ Display for diagnostic information error Diagnostic information 3 Diagnostic information 1 Unit status Diagnostic information 2...
  • Page 76 2) Valve ¥ ¥ - Description display (valve) Display Description Part No Wireless Base/Remote product number. Mapped position for the valve. Displays the mapped position of the selected digital input Unit No. unit. Refer to "5.3.2 Properties", "Unit address order" for details on mapped position. Displays the mapped diagnostic data bits for the selected valve.
  • Page 77 IO unit (digital) 5.1.4.2 Digital input unit (product number: EX600-DX#D) ¥ ¥ Digital output unit (product number: EX600-DY#B) ¥ ¥ -76- No.EX##-OMV0017-J...
  • Page 78 Digital input / output unit (product number: EX600-DM#F) ¥ ¥ ¥ - Description display (digital unit) Display Description Part No Displays the product number of the digital unit (input, output, input / output). Displays the mapped position of the digital unit (input, output, input / output). Unit No.
  • Page 79 IO unit (analog) 5.1.4.3 Analog input unit (product number: EX600-AXA) Status display: No error: (OK) Error: (name of error) Analog output unit (product number: EX600-AYA) Status display: No error: (OK) Error: (name of error) -78- No.EX##-OMV0017-J...
  • Page 80 Analog input / output unit (product number: EX600-AMB) ¥ Status display: No error: (OK) Error: (name of error) - Description display (analog unit) Display Description Part No Displays the product number of the analog unit (input, output, input / output). Displays the mapped position of the analog unit (input, output, input / output).
  • Page 81 Logger unit (product number: EXW1-RDX#G4C#) ¥ Open a LoggingViewer window. -80- No.EX##-OMV0017-J...
  • Page 82 LoggingViewer (product number: EXW1-RDX#G4C#) - Description display Display Description Channel Select a Timer Ch No. . Export Log data can be exported to text files. Reload the parameters of the selected “Channel”. Reload Clear Clear the log data. Log data Log data for the selected item is displayed.
  • Page 83: I/O Monitor Tab

    I/O monitor tab In the I/O monitor tab, the wireless unit I/O mapping data can be monitored when the power status is "Power on". Diagnostic information or details of input / output can be checked by double-clicking any address line in the display.
  • Page 84: Output Tab

    Output tab 5.2.2 The output tab shows the output mapping information of the wireless unit. ¥ ¥ - Output display Display Description Displayed items Forced output mode can be selected by clicking Check marked: Forced output on Enforce ON [Enforce ON]. Not check marked: Forced output off * Refer to "4.4 Forced output"...
  • Page 85: Io Details

    IO details 5.2.3 The IO Details window will open by double-clicking the line of an address of the I/O unit which is connected to the wireless unit. ¥ ¥ Double-click -84- No.EX##-OMV0017-J...
  • Page 86 IO unit information and input / output data can be checked in the IO Detail window. The diagnostic error type is represented by different background colours. The meaning of a background colour can be checked by clicking [>>]. - Background colour Background Display Description...
  • Page 87: Information Tab, Description

    Information tab, description 5.2.4 Wireless unit (manifold type (valve)) 5.2.4.1 ¥ ¥ ¥ - IO details (manifold type (valve)) Display Description Displays the PID of the Wireless Base/Remote to which the selected valve is connected. Unit TAG Displays the tag of the Wireless Base/Remote to which the selected valve is connected. Displays the channel name of the Wireless Base/Remote to which the selected valve is W.ch connected.
  • Page 88 IO unit (digital) 5.2.4.2 Digital input unit (product number: EX600-DX#D) ¥ ¥ Digital output unit (product number: EX600-DY#B) ¥ ¥ -87- No.EX##-OMV0017-J...
  • Page 89 Digital input / output unit (product number: EX600-DM#F) ¥ ¥ ¥ - IO unit information (digital unit) Display Description Displays the PID of the Wireless Base/Remote to which the digital unit (input, output, input / output) is connected. Displays the tag of the Wireless Base/Remote to which the digital unit (input, output, input / Unit TAG output) is connected.
  • Page 90 IO unit (analog) 5.2.4.3 Analog input unit (product number: EX600-AXA) IO unit information ¥ Status display: Input / output value of the ¥ ¥ No error: (OK) channel Error: (name of error) Analog output unit (product number: EX600-AYA) ¥ IO unit information Status display: No error: (OK) ¥...
  • Page 91 Analog input / output unit (product number: EX600-AMB) IO unit information ¥ Status display: No error: (OK) Error: (name of error) Input / output value of the channel - IO unit information (analog unit) Display Description Displays the PID of the Wireless Base/Remote to which the analog unit (input, output, input / output) is connected.
  • Page 92 - Channel status (analog output unit) Data format Displayed analog value +/-□□□ mA (current range) 12-bit resolution, 11-bit resolution +/-□□□ V (voltage range) +/-□□---□ Scaled - Channel status (analog input / output unit) Data format Displayed analog value +/-□□□ mA (current range): Input or output value 12-bit resolution, 11-bit resolution +/-□□□...
  • Page 93: Properties Tab

    Properties tab The settings of the currently connected wireless unit can be changed in the Properties tab. The procedure consists of a control panel and parameters. ¥ ¥ Control panel Parameters -92- No.EX##-OMV0017-J...
  • Page 94: Control Panel

    Control panel 5.3.1 A control panel for changing the displayed parameters consists of 4 radio buttons and 3 buttons. ¥ ¥ - Radio buttons for selecting the parameters to display (Base unit). Name Function Switch to the Base unit parameters. Occupied points for the module input / output can Base setting be set.
  • Page 95: Properties

    - Control panel buttons Name Functions Set parameters are reflected once power is supplied to the wireless unit. Click Reset module [Reset module] in order to reflect parameters that were set while power was still being supplied. Button to export the configuration of the wireless unit to a PC (saved as file type Export ".smc").
  • Page 96 - Base unit parameters Parameter Set value Initial value Description name Define all settings that are in output operation status when fieldbus communication is disconnected. CLEAR: Clear the output. CLEAR HOLD/CLR CLEAR HOLD: Fix the output at the current value. HOLD (unit) Software Control: CLEAR, HOLD or SET for individual...
  • Page 97 (2) Ethernet setting Ethernet setting display. Displayed for a Base unit that supports EtherNet/IP. ¥ ¥ - Wireless Base manifold type (EX600-WEN*) Parameter name Set value Initial value Note MAC address MAC address of the product is displayed. Select the IP address setting mode. Select the mode suitable for your network environment.
  • Page 98 - The compact Wireless Base (EXW1-BENAC1) Parameter name Set value Initial value Note MAC address MAC address of the product is displayed. Select the IP address setting mode. Select the mode suitable for your network environment. Manual: The IP address is set by inputting it directly. DHCP: The IP address is set automatically via the DHCP Manual / DHCP / server.
  • Page 99 (3) CC-Link setting CC-Link setting display. Displayed for a Base unit that supports CC-Link (EXW1-BMJA#). ¥ ¥ - CC-Link parameters Parameter name Set value Initial value Note Operating mode 1 to 8 CC-Link version, number of occupied stations, etc. 156 kbps / 625 kbps Set the communication speed.
  • Page 100 (a) Operating mode setting This setting specifies a CC-Link operating mode. Setting range: 1 to 8 CC-Link setting Occupied area Number of Operating Number of registerable Bit area Word area mode CC-Link Ver. Extended cyclic occupied units RX/RY RWr/RWw stations 1.10 64/64 1.10...
  • Page 101 (4) System setting System setting display. ¥ ¥ -100- No.EX##-OMV0017-J...
  • Page 102 - Compact Wireless Base (EXW1-BMJA#) Parameter Set value Initial value Note I/O mapping Manual Manual Specifies an I/O mapping method. * "Manual" is fixed for EXW1-BMJA#. Diagnostic Advanced Advanced Specifies diagnostic information to map to the Word area. allocation Setting range: Advanced Detailed (System diagnosis + Remote connection / diagnosis / registration information) * "Advanced"...
  • Page 103 - Compact Wireless Base (EXW1-BDNAC) Parameter Set value Initial value Note I/O mapping Manual / Auto Manual Specifies an I/O mapping method. System input 16, 128, 256, 512, 1280 points/ Set the number of inputs which can be controlled by the entire size 768, 1024, 1280, 160 byte...
  • Page 104 - Compact Wireless Base (EXW1-BDNAC) (continued) Parameter Set value Initial value Note Time Unsynchroni The time information is the time that the product recognizes. It is Information used for a timestamping event and other logs. Until "synchronization" is performed, it displays the time elapsed since startup.
  • Page 105 - Compact Wireless Base (EXW1-BECAC) Parameter Set value Initial value Note I/O mapping Auto Auto Specifies an I/O mapping method. * " Auto" is fixed for EXW1-BECAC. Diagnostic None / Simple / Advanced Set the diagnostic information allocated to the I/O map. Refer to the allocation Advanced "Diagnostic allocation"...
  • Page 106 - Compact Wireless Base (EXW1-BENAC1) Parameter Set value Initial value Note I/O mapping Manual / Auto Manual Specifies an I/O mapping method. System input 16, 128, 256, 512, 2048 points/ Set the number of inputs which can be controlled by the entire size 768, 1024, 1280, 256 byte...
  • Page 107 - Compact Wireless Base (EXW1-BENAC1) (continued) Parameter Set value Initial value Note Time Unsynchroni The time information is the time that the product recognizes. It is Information used for a timestamping event and other logs. Until "synchronization" is performed, it displays the time elapsed since startup.
  • Page 108 - Compact Wireless Base (EXW1-BPNAC1) Parameter Set value Initial value Note I/O mapping Auto Auto Specifies an I/O mapping method. * " Auto" is fixed for EXW1-BPNAC1. Diagnostic None / Simple / Advanced Set the diagnostic information allocated to the I/O map. Refer to the allocation Advanced "Diagnostic allocation"...
  • Page 109 - Wireless unit (manifold type) (EX600-WEN# / EX600-WPN# etc.) Parameter Set value Initial value Note I/O mapping Manual / Auto Manual Define the I/O mapping of the entire wireless system including the (EX600- Wireless Remote unit registered to the Wireless Base unit. WEN#) Auto: All I/O points mapped to the Wireless Base unit and Wireless Remote unit are identified and mapped automatically.
  • Page 110 ⚫ Protocol setting Refer to the table below for wireless communication protocols. To pair an EXW1-series unit with an EX600-W-series unit, V.1.0 must be set. This also applies when building a wireless system consisting of both EXW1 and EX600-W series. - V.1.0: The same wireless communication method as EX600-W is used, and the [frequency channel selecting function (F.C.S.)] are not available.
  • Page 111 (5) Remote registration For this wireless system, it is necessary to register the PID for each product to establish communication without interference from another network. The Remote unit registration display consists of "Registered Remotes", "Remote registration buttons", "Free Remotes", "Pairing", and "Dummy" items. * Registration of Remotes needs to be performed with power supplied.
  • Page 112 (5)-b Remote registration buttons Remote registration buttons are only enabled when wireless units are in pairing mode. - Remote registration button display Display Description Select the channel used to register the Remote to the Wireless Base. W.ch (Only channels available for registration will be displayed) Move the Wireless Remote from Free Remotes to Registered Remotes.
  • Page 113 (5)-d Pairing The radio buttons used for pairing are only settable in Administrator mode. They can be set even when power is off. - Pairing radio button display Item Description Change to normal (non-pairing) mode. Indicates that the current status is Normal (pairing Normal mode disabled) mode.
  • Page 114 (5)-f FCS Setting (Frequency Channel Select) The frequency channel can be selected using this function. This function is only supported by protocol V.2.0. Specify protocol V.2.0 in [System setting]. FCS Setting cannot be used if communication with subordinate Remotes uses a mixture of protocols. Ensure that only Remote units that support protocol V.2.0 are registered to the Base with which FCS Setting is to be used.
  • Page 115 The Frequency Channel Select Window is displayed. Item Description Read button Retrieves the current channel selection configuration. The W-LAN indicators make it possible to select frequency channels corresponding to W-LAN Channel W-LAN channel at one time. (2) indicators * In the example above, W-LAN Channel: CH.10 is selected. The W-CH indicators make it possible to select frequencies for each CH.
  • Page 116 (6) Remote setting The parameters of a Remote unit can be changed as required. ¥ ¥ -115- No.EX##-OMV0017-J...
  • Page 117 - Remote parameters Compact wireless unit (EXW1-RDX#E4## / EXW1-RDY#E4## / EXW1-RDM#E3## etc.) Parameter Set value Initial value Note Fixed 16 points 16 points For the EXW1-RD#, the number is fixed at 16 (16 bits). Input size* (16 bits) (16 bits) * Although the number of occupied inputs of EXW1-RDM# is fixed at 16 (16 bits), only the lower 8 bits are available.
  • Page 118 Wireless unit (manifold type) (EX600-WSV#) Parameter Set value Initial value Note Define all settings that are in the output operation status when fieldbus communication is disconnected. CLEAR: Clear the output. HOLD/CLR CLEAR / HOLD / HOLD: Fix the output at the current value. CLEAR (unit) Software Control...
  • Page 119 (7) Pairing setting Setting for wireless communication between the Wireless Base unit and Wireless Remote unit. It is necessary to set the operating mode to pairing when registering the Wireless Remote to Wireless Base. ¥ ¥ - Radio buttons for selecting the pairing mode. Item Description Change to normal (non-pairing) mode.
  • Page 120: Event Tab

    Event tab The Event tab makes it possible to check the event information (errors, etc.) of the Wireless Base. ¥ ¥ - Event tab display Display Description Model selection Select a Wireless Remote registered to the Base. Clear Event Data Clear the event data from the selected unit in “Model selection”.
  • Page 121 ● Error codes The table below shows error codes with corresponding details and diagnostics maps. Diagnostics map Bit no. Error code Description Item Except for EXW1-BMJ EXW1-BMJ Detection of a short circuit of US1 or 6 or 7 Detection of the range upper limit Detection of the range lower limit Detection of unconnected load System...
  • Page 122: Wireless Tab

    Wireless tab The Wireless tab displays the wireless log data. ¥ ¥ - Wireless tab display Display Description Received data for the Wireless Base is displayed on the Input / Output tabs Input tab, and sent data is displayed on the Output tab. The wireless channel is displayed.
  • Page 123: Parameter Tab

    Parameter tab Parameter tab consists of 2 areas, "System configuration" and "Parameter". The parameters of unit can be changed as required. ¥ - Wireless tab display Display Description Click to display remote unit parameters in the parameter Part No. area. Click to display the parameters of the selected IO unit in the Unit No.
  • Page 124: Wireless System Parameter List

    6. List of Wireless system parameter unit Product Number Description EXW1-BMJA* CC-Link EXW1-BDNAC DeviceNet EXW1-BECAC EtherCAT Wireless Base EXW1-BENAC1 EtherNet/IP EXW1-BPNAC1 PROFINET EX600-WEN* EtherNet/IP EX600-WPN* PROFINET EXW1-RDY*M5C Digital output Valve manifold EXW1-RDX*G4C* Digital input M12 connector Grommet EXW1-RDY*G4C* Digital output M12 connector Grommet EXW1-RDM*G3C* Digital input / output M12 connector Grommet EXW1-RDX*E4**...
  • Page 125 - Wireless Base unit (EX600-WEN#) setting parameters Setting Classificat Parameter name Set value Initial value when Note power is off Setting the output operation when the HOLD/CLR CLEAR / HOLD / Software CLEAR Available fieldbus communication is (unit) Control disconnected. 0 to 128 points (0 to 16 bytes) 128 points / b) Input size...
  • Page 126 Setting Classificati Parameter name Set value Initial value when Note power is off Normal mode: Wireless Remote cannot be registered. a) Pairing Normal / pairing modes Normal mode Available (Communication with the registered Remote will be established). Pairing mode: Remote Wireless Remote can be registered.
  • Page 127 - Wireless Base unit (EX600-WPN#) setting parameters Setting Classification Parameter name Set value Initial value when Note power is off Setting the output operation when HOLD/CLR CLEAR / HOLD / Software CLEAR Available the fieldbus communication is (unit) Control disconnected. 0 to 128 points (0 to 16 bytes) 128 points /...
  • Page 128 - Compact Wireless Base unit (EXW1-BMJA#) setting parameters Setting Initial when Classification Parameter name Set value Note value power is Operating 1 to 8 Available mode CC-Link 156 kbps / 625 kbps / 2.5 Mbps / b) Speed 156 kbps Available setting 5 Mbps / 10 Mbps...
  • Page 129 - Compact Wireless Base unit (EXW1-BECAC) setting parameters Setting Initial when Classification Parameter name Set value Note value power is EtherCAT a) Custom setting Enable / Disable Disable Setting available a) I/O mapping Auto Auto Available Fixed at "Auto". Diagnostic information is allocated Diagnostic None / Simple / Advanced Advanced Available...
  • Page 130 - Compact Wireless Base unit (EXW1-BENAC1) setting parameters Setting when Classification Parameter name Set value Initial value Note power is When the total size (byte) of the I/O mapping is an odd number, 1 a) I/O mapping Manual / Auto Manual Available byte will be added automatically...
  • Page 131 - Compact Wireless Base unit (EXW1-BENAC1) setting parameters (continued) Setting when Classification Parameter name Set value Initial value Note power is a) Security Mode Sign & Encrypt / Sign / None Sign & Encrypt Available Basic256Sha256 Enable Enable Aes128_Sha256_ This is not settable Enable Enable Security...
  • Page 132 - Compact Wireless Base unit (EXW1-BPNAC1) setting parameters Setting when Classification Parameter name Set value Initial value Note power is a) I/O mapping Auto Auto Available Fixed at "Auto". Diagnostic information is allocated to the head d) Diagnostic allocation None / Simple / Advanced Advanced Available of the input data of the...
  • Page 133 - Compact Wireless Base unit (EXW1-BDNAC) setting parameters Setting when Classification Parameter name Set value Initial value Note power is When the total size (byte) of the I/O mapping is an odd number, 1 a) I/O mapping Manual / Auto Manual Available byte will be added automatically...
  • Page 134 - Compact Wireless Remote unit (EXW1-RDY#M5C) setting parameters Setting Classificat Parameter name Set value Initial value when power Note is off Brown-out Enable/Disable Enable Detection for US1 available Brown-out Enable/Disable Disable Parameter Detection for US2 available Output State Clear/Hold Remote Clear Fieldbus FaultIdle /Individual...
  • Page 135 - Compact Wireless Remote unit (EXW1-RDY#M5C) setting parameters (continued) Setting Classificat Parameter name Set value Initial value when power Note is off 0: Turn off the output Ch 7-0: 1: Turn on the output forcefully Output State for 0x00-0xFF 0x00 Bit0:Channel 0 available Fieldbus Fault...
  • Page 136 - Compact Wireless Remote unit (EXW1-RDY#M5C) setting parameters (continued) Setting Classificat Parameter name Set value Initial value when power Note is off 0: Turn off the output Ch 7-0: 1: Turn on the output forcefully Bit0:Channel 0 Output State for 0x00-0xFF 0x00 available...
  • Page 137 - Compact Wireless Remote unit (EXW1-RDY#M5C) setting parameters (continued) Setting Classificat Parameter name Set value Initial value when power Note is off 0: Turn off the output Ch 7-0: 1: Turn on the output forcefully Output State for 0x00-0xFF 0x00 Bit0:Channel 0 available RF TimeOut...
  • Page 138: Clr(Clear

    - Compact Wireless Remote unit (EXW1-RDY#M5C) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 Ch #:ON/OFF Counter ON/OFF count upper limit value (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded 0x00-0xFF...
  • Page 139 - Compact Wireless Remote unit (EXW1-RDY#M5C) diagnostic parameters (continued) Classification Parameter name Display value Note 0: No error 1: Error Ch 7-0:Short Circuit 0x00-0xFF Bit0: There is an error in channel 0. Detection(Output) Bit7: There is an error in channel 7. 0: No error 1: Error Ch 15-8: Short Circuit...
  • Page 140 - Compact Wireless Remote unit (EXW1-RDX#G4C#) setting parameters Classificat Setting when Parameter name Set value Initial value Note power is off a) Brown-out Detection for US1 Enable/Disable Enable Not available Parameter b) LED OFF Enable/Disable Disable Not available Remote a) Short Circuit Detection(Power) Enable/Disable Enable Not available...
  • Page 141 - Compact Wireless Remote unit (EXW1-RDX#G4C#) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 ON/OFF count upper limit value Ch #:ON/OFF Counter (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded ON/OFF 0x00-0xFF...
  • Page 142 - Compact Wireless Remote unit (EXW1-RDY#G4C#) setting parameters Setting Classificat when Parameter name Set value Initial value Note power is Brown-out Enable/Disable Enable Detection for US1 available Brown-out Enable/Disable Disable Detection for US2 available Parameter Output State Clear/Hold Clear Fieldbus FaultIdle /Individual available Remote...
  • Page 143 - Compact Wireless Remote unit (EXW1-RDY#G4C#) setting parameters (continued) Setting Classificat Parameter name Set value Initial value when power Note is off 0: Hold the output Ch 7-0: 1: Depend on output state Bit0:Channel 0 Hold State for 0x00-0xFF 0xFF available Fieldbus Idel Bit7:Channel 7...
  • Page 144 - Compact Wireless Remote unit (EXW1-RDY#G4C#) setting parameters (continued) Setting Classificat Parameter name Set value Initial value when power Note is off 1: Generates an error. Ch 7-0: 0; Does not generate an error. ON/OFF Counter 0x00-0xFF 0x00 Bit0:Channel 0 available Limit Detection Bit7:Channel 7...
  • Page 145 - Compact Wireless Remote unit (EXW1-RDY#G4C#) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 Ch #:ON/OFF Counter ON/OFF count upper limit value (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded 0x00-0xFF...
  • Page 146 - Compact Wireless Remote unit (EXW1-RDM#G3C#) setting parameters Setting Classificat when Parameter name Set value Initial value Note power is Brown-out Enable/Disable Enable Detection for US1 available Brown-out Enable/Disable Disable Detection for US2 available Parameter Output State Clear/Hold Clear Fieldbus FaultIdle /Individual available Remote...
  • Page 147 - Compact Wireless Remote unit (EXW1-RDM#G3C#) setting parameters (continued) Setting Classificat when Parameter name Set value Initial value Note power is Short Circuit Enable/Disable Enable Detection(Output) available Restart After Auto/Manual Manual ShortCircuit available 1: Generates an error. Ch 7-0: 0; Does not generate an error. Open Circuit 0x00-0xFF 0x00...
  • Page 148 - Compact Wireless Remote unit (EXW1-RDM#G3C#) setting parameters (continued) Classificat Initial Setting when Parameter name Set value Note value power is off In_Ch0 - In_Ch7, Not available Out_Ch0 - Out_Ch7 Measurement Rising_Edge Start Trigger Falling_Edge Not available Ch #: *1:Depend on Ch #. Both_Edges Timer Please refer to the instruction...
  • Page 149 - Compact Wireless Remote unit (EXW1-RDM#G3C#) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 ON/OFF count upper limit value (0 to 0xFFFFFFFF) a) Ch #:ON/OFF Counter Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded ON/OFF Parameter Tab...
  • Page 150 - Compact Wireless Remote unit (EXW1-RDM#G3C#) diagnostic parameters (continued) Classification Parameter name Display value Note 0: No error 1: Error Ch 7-0:Exceeded specified 0x00-0xFF Bit0: There is an error in channel 0. Limit Bit7: There is an error in channel 7. 0: No error 1: Error Ch 15-8:Exceeded specified...
  • Page 151 - Compact Wireless Remote unit (EXW1-RDX#E4##) setting parameters Setting Classificat Parameter name Set value Initial value when power Note is off a) Input size 16 points / 2 byte 16 points / 2 byte Fixed b) Output size 0 points / 0 byte 0 points / 0 byte Fixed Wireless...
  • Page 152 - Compact Wireless Remote unit (EXW1-RDX#E4##) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 ON/OFF count upper limit value Ch #:ON/OFF Counter (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded ON/OFF 0x00-0xFF...
  • Page 153 - Compact Wireless Remote unit (EXW1-RDY#E4##) setting parameters Setting Classificat Parameter name Set value Initial value when power Note is off a) Input size 0 points / 0 byte 0 points / 0 byte Fixed b) Output size 16 points / 2 byte 16 points / 2 byte Fixed Wireless...
  • Page 154 - Compact Wireless Remote unit (EXW1-RDY#E4##) setting parameters (continued) Classificat Setting when Parameter name Set value Initial value Note power is off Short Circuit Enable/Disable Enable Not available Detection(Output) b) Restart After ShortCircuit Auto/Manual Manual Not available 1: Generates an error. Ch 7-0: 0;...
  • Page 155 - Compact Wireless Remote unit (EXW1-RDY#E4##) setting parameters (continued) Classificat Setting when Parameter name Set value Initial value Note power is off 0: Hold the output Ch 7-0: 1: Depend on output state Bit0:Channel 0 Hold State for Fieldbus 0x00-0xFF 0xFF Not available Idel...
  • Page 156 - Compact Wireless Remote unit (EXW1-RDY#E4##) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 Ch #:ON/OFF Counter ON/OFF count upper limit value (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded 0x00-0xFF...
  • Page 157 - Compact Wireless Remote unit (EXW1-RDM#E3##) setting parameters Classificati Setting when Parameter name Set value Initial value Note power is off a) Input size 16 points / 2 byte 16 points / 2 byte Fixed b) Output size 16 points / 2 byte 16 points / 2 byte Fixed If set to "Idle", the wireless c) Wireless signal...
  • Page 158 - Compact Wireless Remote unit (EXW1-RDM#E3##) setting parameters (continued) Classificati Setting when Parameter name Set value Initial value Note power is off Short Circuit Enable/Disable Enable Not available Detection(Output) b) Restart After ShortCircuit Auto/Manual Manual Not available 1: Generates an error. Ch 7-0: 0;...
  • Page 159 - Compact Wireless Remote unit (EXW1-RDM#E3##) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 ON/OFF count upper limit value (0 to 0xFFFFFFFF) a) Ch #:ON/OFF Counter Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded ON/OFF Parameter Tab...
  • Page 160 - Compact Wireless Remote unit (EXW1-RAXZA2C) setting parameters Setting Classificati Parameter name Set value Initial value when power Note is off Unit:Brown-out Detection Generated error when US1 Enable/Disable Enable for US1 available power supply voltage. Unit:Short Circuit Enable/Disable Enable Detect the short circuit condition. Detection(Power) available Little Endian /...
  • Page 161 - Compact Wireless Remote unit (EXW1-RAXZA2C) diagnostic parameters Classification Parameter name Display value Note Short Circuit No error / Detect a short circuit for the analog input power. Detection(Input) Error User Setting Value Upper No error / Detect the Upper limit error or scale 0% > 100%. Limit Error Error (when using scale conversion format) Error...
  • Page 162 - Compact Wireless Remote unit (EXW1-RLAPA8C(ClassA)) setting parameters Classificati Initial Setting when Parameter name Set value Note value power is off Generated error when US1 power supply voltage goes under a) Brown-out Detection for US1 Enable/Disable Enable Not available approx. 16 V. Either of the following: Short Circuit Detection(L+, •L+ power supply...
  • Page 163 - Compact Wireless Remote unit (EXW1-RLAPA8C(ClassA)) setting parameters (continued) Setting Classificat Parameter when Set value Initial value Note name power is Swap the byte order of the process Pd Byte Direct / Swap 16 bit / Swap 32 bit / data, which is exchanged between Direct Swap all...
  • Page 164 - Compact Wireless Remote unit (EXW1-RLBPA7C(ClassB)) setting parameters Setting Classificati Parameter name Set value Initial value when power Note is off Generated error when US1 power supply voltage goes under a) Brown-out Detection for US1 Enable/Disable Enable available approx. 16 V. Generated error when US2 power supply voltage...
  • Page 165 - Compact Wireless Remote unit (EXW1-RLBPA7C(ClassB)) setting parameters (continued) Setting Classificat Parameter when Set value Initial value Note name power is Swap the byte order of the process Pd Byte Direct / Swap 16 bit / Swap 32 bit / data, which is exchanged between Direct Swap all...
  • Page 166 - Compact Wireless Remote unit (EXW1-RLAPA8C(ClassA) / EXW1-RLBPA7C(ClassB)) diagnostic parameters Classification Parameter name Display value Note NO_DEVICE、 DEACTIVATED、 PORT_DIAG PREOPERATE、 a) PortStatusInfo OPERATE、 DI_C/Q、 DO_C/Q 0: Process data valid 1: process data invalid Bit0:input b) PortQualityInfo 0x00 to 0xFF Bit1:output Bit2 to 7:Reserved c) RevisionID 0x00-0xFF...
  • Page 167 - Wireless Remote unit (EXA1-20-SA/EXA1-30-SA/EXA1-40-SA/EXA1-60-SA) setting parameters Classificati Setting when Parameter name Set value Initial value Note power is off a) Brown-out Detection for US1 Enable/Disable Enable Not available Parameter b) Communication failure Clear/Hold Hold Not available Short Circuit Detection Enable/Disable Enable Not available...
  • Page 168 - Wireless Remote unit (EXA1-20-SA/EXA1-30-SA/EXA1-40-SA/EXA1-60-SA) setting parameters (continued) Classificati Setting when Parameter name Set value Initial value Note power is off Direct / Swap 16 bit / a) Pd Byte swap Enable Not available Swap 32 bit / Swap all Power ON / 1:Power b) L+ Power On Not available...
  • Page 169 - Wireless Remote unit (manifold type) (EX600-WSV#) setting parameters Setting Classificat Initial Parameter name Set value when Note value power is off Setting the output operation when the CLEAR / HOLD / Software a) HOLD/CLR (unit) CLEAR Available fieldbus communication is Control disconnected.
  • Page 170 - Wireless Remote EX600-WSV valve manifold unit (EX600-WSV) setting parameters Setting Classificati Parameter name Set value Initial value when power Note is off Unit:Short Circuit Enable/Disable Enable Detection(OUTPUT) available Unit:Restart After Auto/Manual Manual Short Circuit available 1: Generates an error. 0;...
  • Page 171 - Wireless Remote EX600-WSV valve manifold unit (EX600-WSV) setting parameters (continued) Setting Classificati Parameter name Set value Initial value when power Note is off 0: Turn off the output Ch 7-0: 1: Turn on the output forcefully Bit0:Channel 0 OUTPUT State for Fieldbus 0x00 to 0xFF 0x00 available...
  • Page 172 - Wireless Remote EX600-WSV valve manifold unit (EX600-WSV) setting parameters (continued) Setting Classificati Parameter name Set value Initial value when power Note is off 0: Turn off the output Ch 7-0: 1: Turn on the output forcefully Bit0:Channel 0 OUTPUT State for Fieldbus 0x00 to 0xFF 0x00 available...
  • Page 173: Clr(Clear

    - Wireless Remote EX600-WSV valve manifold unit (EX600-WSV) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 Ch #:ON/OFF Counter ON/OFF count upper limit value (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded 0x00-0xFF...
  • Page 174 - Wireless Remote EX600-WSV valve manifold unit (EX600-WSV) diagnostic parameters (continued) Classification Parameter name Display value Note 0: No error 1: Error Ch 7-0:Short Circuit 0x00-0xFF Bit0: There is an error in channel 0. Detection(OUTPUT) Bit7: There is an error in channel 7. 0: No error 1: Error Ch 15-8: Short Circuit...
  • Page 175 - Wireless Remote EX600-WSV Digital input unit (EX600-DX**) setting parameters Setting Classificati Parameter name Set value Initial value when power Note is off Unit:Short Circuit Enable/Disable Enable Detection(Power) available b) Unit:Inrush Current Filter Enable/Disable Disable available c) Unit:INPUT Filtering Time 0.1/1.0/10/20ms 1.0ms available...
  • Page 176 - Wireless Remote EX600-WSV Digital input unit (EX600-DX**) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 Ch #:ON/OFF Counter ON/OFF count upper limit value (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded 0x00-0xFF...
  • Page 177 - Wireless Remote EX600-WSV Digital output unit (EX600-DY**) setting parameters Setting Classificati Parameter name Set value Initial value when power Note is off Unit:Short Circuit Enable / Disable Enable Detection(OUTPUT) available Unit:Restart After Auto / Manual Manual Short Circuit available 1: Generates an error.
  • Page 178 - Wireless Remote EX600-WSV Digital output unit (EX600-DY**) setting parameters (continued) Setting Classificati Parameter name Set value Initial value when power Note is off 0: Hold the output 1: Depend on output state Ch 7-0: Bit0:Channel 0 0x00 to 0xFF 0xFF Hold State for Fieldbus Idle available...
  • Page 179 - Wireless Remote EX600-WSV Digital input unit (EX600-DY**) diagnostic parameters Classification Parameter name Display value Note 0 — 4294967295 Ch #:ON/OFF Counter ON/OFF count upper limit value (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded 0x00-0xFF...
  • Page 180 - Wireless Remote EX600-WSV Digital input / output unit (EX600-DM**) setting parameters for input Setting Classificati Parameter name Set value Initial value when power Note is off Unit:Short Circuit Enable/Disable Enable Detection(Power) available b) Unit:Inrush Current Filter Enable/Disable Disable available c) Unit:INPUT Filtering Time 0.1/1.0/10/20ms 1.0ms...
  • Page 181 - Wireless Remote EX600-WSV Digital input / output unit (EX600-DM**) setting parameters for output Setting Classificati Parameter name Set value Initial value when power Note is off Unit:Short Circuit Enable / Disable Enable Detection(OUTPUT) available Unit:Restart After Auto / Manual Manual Short Circuit available...
  • Page 182 - Wireless Remote EX600-WSV Digital input / output unit (EX600-DM**) diagnostic parameters for output Classification Parameter name Display value Note 0 — 4294967295 Ch #:ON/OFF Counter ON/OFF count upper limit value (0 to 0xFFFFFFFF) Value Clr(Clear) Clears the Input ON/OFF counter to 0. 0: No error 1: Error Ch 7-0:Exceeded...
  • Page 183 - Wireless Remote EX600-WSV Analog input unit (EX600-AX*) setting parameters Setting Classificati Parameter name Set value Initial value when power Note is off Offset binary/ Signed magnitude/ a) Unit:Analog Data Format Offset binary 2’s complement/ available Scaled(AXB only) -10..+10 V/ _-5..+5 _V/ Selects the analogue input __0..10 V/...
  • Page 184 - Wireless Remote EX600-WSV Analog input unit (EX600-AX*) diagnostic parameters Classification Parameter name Display value Note 0: No error 1: Error Bit0:Channel 0 Bit1:Channel 1 Ch 7-0:Short Circuit Bit2:Channel 2 (available AXB) 0x00-0xFF Detection(INPUT) Bit3:Channel 3 (available AXB) Bit4: 0 (N/A) Bit7: 0 (N/A) 0: No error 1: Error...
  • Page 185 - Wireless Remote EX600-WSV Analog output unit (EX600-AYA) setting parameters Setting Classificati Parameter name Set value Initial value when power Note is off Offset binary/ Signed magnitude/ Unit:Analog Data Format Offset binary 2’s complement/ available Scaled __0..10 V/ __0..5 _V/ Selects the analogue input Ch #: Analog Range __1..5 _V/...
  • Page 186 - Wireless Remote EX600-WSV Analog output unit (EX600-AYA) diagnostic parameters Classification Parameter name Display value Note 0: No error 1: Error Bit0:Channel 0 Ch 7-0:Short Circuit Bit1:Channel 1 0x00-0xFF Detection(INPUT) Bit2: 0 (N/A) Bit7: 0 (N/A) 0: No error 1: Error Bit0:Channel 0 Ch 7-0: User Setting Bit1:Channel 1...
  • Page 187 - Wireless Remote EX600-WSV Analog input / output unit (EX600-AMB) setting parameters for input Setting Classificati Parameter name Set value Initial value when power Note is off Offset binary/ Signed magnitude/ a) Unit:Analog Data Format Offset binary 2’s complement/ available Scaled __0..10 V/ __0..5 _V/...
  • Page 188 - Wireless Remote EX600-WSV Analog input / output unit (EX600-AMB) diagnostic parameters for input Classification Parameter name Display value Note 0: No error 1: Error Bit0:Channel 0 Ch 7-0:Short Circuit Bit1:Channel 1 0x00-0xFF Detection(INPUT) Bit2: 0 (N/A) Bit7: 0 (N/A) 0: No error 1: Error Bit0:Channel 0...
  • Page 189 - Wireless Remote EX600-WSV Analog input / output unit (EX600-AMB) setting parameters for output Setting Classificati Parameter name Set value Initial value when power Note is off Offset binary/ Signed magnitude/ Unit:Analog Data Format Offset binary 2’s complement/ available Scaled __0..10 V/ __0..5 _V/ Selects the analogue input...
  • Page 190 - Wireless Remote EX600-WSV Analog input / output unit (EX600-AMB) diagnostic parameters Classification Parameter name Display value Note 0: No error 1: Error Bit0:Channel 0 Ch 7-0:Short Circuit Bit1:Channel 1 0x00-0xFF Detection(INPUT) Bit2: 0 (N/A) Bit7: 0 (N/A) 0: No error 1: Error Bit0:Channel 0 Ch 7-0: User Setting...
  • Page 191 - Parameters in common with Wireless Base units and Wireless Remote units Setting when Classification Parameter name Set value Initial value Note power is off Part No (EX600-WEN#) (EX600-WPN#) (EX600-WSV#) (EXW1-BMJA#) (EXW1-BDNAC) (EXW1-BECAC) Characters which can be input (EXW1-BENAC1) are half-width characters (EXW1-BPNAC1) (alphabet, numbers, symbols) Information...
  • Page 192: Troubleshooting

    7. Troubleshooting Problem Problem Possible causes Inspection and countermeasures 1: Adjust the NFC reader / writer so that it is positioned at the centre of the NFC antenna 1. The NFC reader / writer (circled part). Unable to read Wireless has moved away from the 2-1: Remove the NFC reader / writer from Base/Remote unit...
  • Page 193 Problem Problem Possible causes Inspection and countermeasures 1. Connected with higher Not possible to change 1. Disconnect the unit from the higher unit. unit. to forced output mode. 2. Login from the Administrator mode. 2. Mode is Monitor mode. The Wireless Remote follows the input / The Wireless Remote The Wireless Remote output size when it was registered to the...
  • Page 194: Specifications / Technical Information / Supplementary Information

    8. Specifications / technical information / supplementary information Terminology Term Definition Administrator mode allows the user to configure the wireless units. Wireless Administrator mode Base/Remote become settable. A broken wire to the input or output equipment has been detected by the diagnostic Broken line detection function.
  • Page 195 Term Definition Occupied points for the module input / Number of I/O points that can be controlled by a module. output Registration of the PID (Product ID) of the Wireless Remote unit to be connected to the Pairing Wireless Base unit. Registration occurs at the initial setting, then the wireless system will activate.
  • Page 196: Revision History

    Revision history Revision Updated content 2.0.0 First edition Version for EX600-WPN# 2.1.0 Common version for EX600-WEN# and EX600-WPN# 2.2.0 ACS reader / writer has been added to verified NFC reader / writers. Remote Control function added to Ethernet setting 2.6.0 Change to wireless unit naming Addition of EXW1 series 2.9.0...
  • Page 197 Applicable models Part Number 2.0.0 2.1.0 2.2.0 2.6.0 2.9.0 2.10.0 2.11.0 2.12.0 2.13.0 2.14.0 2.15.0 Base EX600-WEN# EX600-WPN# EXW1-BMJA# EXW1-BECAC EXW1-BENAC1 EXW1-BPNAC1 EXW1-BDNAC Remote EX600-WSV# EXW1-RDX#E4# EXW1-RDY#E4# EXW1-RDM#E3 EXW1-RL# EXW1-RAXZA2C EXW1-RDM#G3C EXW1-RDX#G4C EXW1-RDY#G4C EXW1-RDY#M5C No.EX##-OMV0017-J...
  • Page 198 Revision history A: Contents revised in several places. [August 2018] B: Contents are added. [August 2018] C: Contents revised in several places. [November 2019] D: Content changes [March 2022] E: Content changes [July 2023] F: Content changes [December 2023] G: Content changes [February 2024] H: Content changes [August 2024] I : Content changes [November 2024] J : Content changes [March 2025]...

Table of Contents