SMC Networks EXW1-BENAC1 Operation Manual page 100

Hide thumbs Also See for EXW1-BENAC1:
Table of Contents

Advertisement

- Wireless unit (manifold type) (EX600-WEN# / EX600-WPN# etc.)
Parameter
Set value
I/O mapping
Manual / Auto
System input
16, 128 to 1280
size
points (2 bytes
to 160 bytes) in
128-point (16-
byte) units
System output
16, 128 to 1280
size
points (2 bytes
to 160 bytes) in
128-point (16-
byte) units
Diagnostic
None / Simple /
allocation
Advanced
Max. Remote
0 / 15 / 31 / 63 /
units
127 Remotes
(EX600-WEN#)
0 / 15 / 31
Remotes
(EX600-WPN#)
DA refresh time
0.1 / 0.2 / 0.5 / 1
(sec) *
1
/ 2 / 5 / 10 / 30 /
60 s
Initial value
Manual
Define the I/O mapping of the entire wireless system including the
(EX600-
Wireless Remote unit registered to the Wireless Base unit.
WEN#)
Auto: All I/O points mapped to the Wireless Base unit and Wireless
Remote unit are identified and mapped automatically.
Auto
(The total number of connected I/O points is the total number of I/O
(EX600-
points set by the diagnostic information, Wireless Base and
WPN#, fixed)
registered Remote Unit.)
Manual: Fixed at the number of I/O points set in "System input size"
and "System output size".
* "Auto" is fixed for EX600-WPN#.
1280 points /
Set the number of inputs which can be controlled by the entire
160 byte
wireless system.
* Number can only be set when "Manual" is used for I/O mapping.
* Cannot be set with EX600-WPN#.
1280 points /
Set the number of outputs which can be controlled by the entire
160 byte
wireless system.
* Number can only be set when "Manual" is used for I/O mapping.
* Cannot be set with EX600-WPN#.
Advanced
Set the diagnostic information allocated to the I/O map. Refer to the
"Diagnostic allocation" section in the Operation Manual (page 56) for
details.
None: No diagnostic data
Simple: System diagnostics
Advanced: System diagnostics + Wireless Remote connection /
diagnostics / registration information
15 Remotes Set the number of Wireless Remote units which are registered to the
Wireless Base unit.
Wireless channels for the number of the set units are enabled.
1 s
Set the data update time of the analog output unit connected to the
Wireless Remote.
* The analog input update time is set for every Wireless Remote unit.
to "
3.3 Remote
-99-
Note
setting".
Refer
No.EX##-OMV0017-G