Display data list
The gyro setting data is divided into the Basic setting and Gyro data (1 to 5) screens and
displayed by the method shown on the right.
- When the S.BUS connection is not used, the gyro data switching function cannot be used, so only [Gyro data 1]
is displayed.
Basic setting screen
Data settings
Tap the [Value], the setting value will be displayed in blue, and [-] and [+] will be displayed
at the bottom of the screen. Touch [+] and [-] to set the data. In the case of selection type,
touch the item to switch the data.
Basic setting
*In the T-FHSS SR mode, the servo position will not adjust until [Write], even if the "Limit" and "Neutral offset" func-
tions are adjusted with [+] and [-].
Response mode
Gyro sensor response setting.
* Low
Middle
High speeds up response.
* In high mode, using the dead band angle is too small, the servo will
work continuously, but there is no problem in running. However, if strong
the servo will work continuously occurs, set to middle or low mode.
Limit
Adjustment function of maximum steering
angle.
* Operate the steering and adjust the left and right
separately so that the maximum steering angle is
obtained as long as the tires do not interfere with
the arms.
* If the adjustment value of the limit is small (the max-
imum steering angle is not adjusted), it becomes
easier to spin.
* During limit adjustment, the steering angle is am-
plified by 1.5 times, but this is not a malfunction.
However, perform drive after completing the limit
adjustment.
SR mode setting
Set to SR mode.
* Set the SR compatible servo to SR only when using
SR mode.
Gyro reading screen
Basic setting screen
Gyro data screen
1/2
2/2
Neutral offset
Neutral adjustment function of the steering
servo.
* Do not use transmitter trim and sub trim. Make the
neutral setting with a gyro.
Reverse
Gyro control direction setting.
* If the car is turned to the left by hand steering
goes out on the right.
Gain mode
Gyro internal control gain switching.
* High gain is 1.5 times more sensitive than standard gain.
* Normally set to standard.
Set to high gain if increasing the sensitivity setting of
the transmitter to the maximum value is not enough.

Advertisement