Download Print this page

FUTABA T10PX Full Manual page 192

Digital proportional r/c system
Hide thumbs Also See for T10PX:

Advertisement

Low battery protection
MC401,402CR/601,602C/850,851C:2.5V 6.0V
MC950CR/MC940,960CR 2.5V 7.5V
Same as Link software Low Bat Protection.
When the power supply voltage drops, the output current to the
motor is limited, and the supply voltage to the receiver is ensured.
When the power supply voltage drops to the set voltage, a protec-
tion circuit operation alarm is activated, and output to the motor is
cut. The protection circuit is automatically reset by the recovery of
the power supply voltage.
Current limiter
MC401,402CR/601,602C/850:50A 300A, INH
MC851C :50A~300A(cannot INH)
MC950CR/MC940,960CR:50A~500A, INH
Same as Link software PWM frequency (at Max. load).
MAX sets the PWM frequency at maximum load at the output current limit value set by
Current Limiter.
Current limiter INH/ACT setting
MC950CR and MC940/960CR tap INH OR ACT by tapping the current limiter INH/ACT.
The MC851C does not have an INH (Off) setting.
Current limit timer
MC401,402CR/601,602C/850,851C:0sec(OFF)240sec
MC940,960CR:0sec(OFF)~240sec (MC950CR cannot)
Same as Link software Current Limit timer.
The output current can be limited up to the set time-lapse from the start of running. This
function is effective in preventing the motor from outputting wasted energy when the voltage
is high immediately after the power battery was recharged.
"Current Limiter (time)" sets the time the output current is limited. This function is disabled
when set to "0" sec.
Since the Current Limit Timer starts when
the throttle is operated to the forward side,
and current is output to the motor, this func-
tion begins to operate when the motor is
run during trim adjustment, etc.
Current limiter (time)
MC401,402CR/601,602C/850,851C :50A~300A
MC940,960CR :50A~500A (MC950CR cannot)
"Current Limit timer" sets the maximum
output current within the time the output
current is limited.

Advertisement

loading