Brake max. duty
All type :0%~100%
Same as Link software Brake Max. Duty.
This setting can set the braking force between the neutral
point and Max brake point.
The larger this value, the higher the braking force. When set
to "0%", the brakes are not valid.
Reverse max. duty
MC401,402CR/MC950CR/MC940,960CR :0%~100%
Same as Link software Reverse Max. Duty.
This setting can set the reverse power between the
neutral point and Max reverse point.
The larger this value, the greater the reverse power.
When set to "0%", the reverse is not active.
Neutral brake
All type :0%~100%
Same as Link software Current Limit timer.
Make this setting when you want to use the brakes at the neutral throttle (OFF) position by
throttle operation. The larger this value, the greater
the braking force. When set to "0%", the neutral
brake is not active.
Reverse mode shift level
MC401,402CR/MC950CR/MC940,960CR :0%~100%
Same as Link software Reverse Mode Shift Level.
The reverse operation can be done with the throttle
trigger to be thrown from brake status to the neutral.
The value can set the amount of the brake in order
to switch to the reverse operation.
Forward BOOST
MC401,402CR/MC601,602C/MC851C :0%~100%
Same as Link software Forward Boost (Boost).
Operation near the throttle trigger neutral position
becomes a sharp rise.
100
50
0
Forward operation
Forward BOOST
"50"
"0"
%
100
50
0
Brake (Reverse) operation
MC401,402CR
MC601,602C
MC950CR
MC850,851C
MC940,960CR
MC401,402CR
MC940,960CR
MC601,602
MC401,402CR
MC950CR
851C