Malfunction Code And Defective Condition Table - Suzuki RMX450Z Service Manual

Table of Contents

Advertisement

Visual Inspection
Prior to diagnosis using the FI indicator light assy or SDS, perform the following visual inspections. The reason for
visual inspection is that mechanical failures (such as oil leakage) cannot be displayed on the screen with the use of FI
indicator light assy or SDS.
• Engine oil level and leakage. Refer to "Engine Oil Filter Replacement" in Section 0B (Page 0B-7).
• Engine coolant level and leakage. Refer to "Cooling Circuit Inspection" in Section 1F (Page 1F-4).
• Fuel level and leakage. Refer to "Fuel Hose Inspection" in Section 0B (Page 0B-14).
• Clogged air cleaner element. Refer to "Air Cleaner Element Cleaning" in Section 0B (Page 0B-4).
• Battery condition.
• Throttle cable play. Refer to "Throttle Cable Play Inspection and Adjustment" in Section 0B (Page 0B-12).
• Broken fuse.
• Exhaust gas leakage and noise. Refer to "Exhaust System Inspection" in Section 1K (Page 1K-3).
• Each coupler disconnection.
• Clogged radiator fins. Refer to "Radiator Inspection and Cleaning" in Section 1F (Page 1F-4).

Malfunction Code and Defective Condition Table

DTC No.
Detected Item
12
CKP sensor
P0335
14
TP sensor
H
P0120
L
15
ECT sensor
H
P0115
L
17
IAP sensor
H
P0105
L
21
IAT sensor
H
P0110
L
Engine General Information and Diagnosis:
Detected Failure Condition
The signal does not reach ECM for 1 sec. or
more, after receiving the IAP sensor input
signal.
The sensor should produce following voltage.
0.5 V ≤ sensor voltage < 4.8 V
In other than the above range, 14 (P0120) is
indicated.
Sensor voltage is higher than specified value.
Sensor voltage is lower than specified value.
The sensor voltage should be the following.
0.1 V ≤ sensor voltage < 4.8 V
In other than the above range, 15 (P0115) is
indicated.
Sensor voltage is higher than specified value.
Sensor voltage is lower than specified value.
The sensor should produce following voltage.
0.5 V ≤ sensor voltage < 4.4 V
In other than the above range, 17 (P0105) is
indicated.
Sensor voltage is higher than specified value.
Sensor voltage is lower than specified value.
The sensor voltage should be the following.
0.2 V ≤ sensor voltage < 4.8 V
In other than the above range, 21 (P0110) is
indicated.
Sensor voltage is higher than specified value.
Sensor voltage is lower than specified value.
BA02J21104009
Check For
CKP sensor wiring and
mechanical parts.
CKP sensor, lead wire/coupler
connection.
TP sensor, lead wire/coupler
connection.
TP sensor circuit shorted to
VCC or ground circuit open.
TP sensor circuit open or
shorted to the ground or VCC
circuit open.
ECT sensor, lead wire/coupler
connection.
ECT sensor circuit open or
ground circuit open.
ECT sensor circuit shorted to
the ground.
IAP sensor, lead wire/coupler
connection.
IAP sensor circuit shorted to
VCC or ground circuit open.
IAP sensor circuit open or
shorted to ground or VCC
circuit open.
IAT sensor, lead wire/coupler
connection.
IAT sensor circuit open or
ground circuit open.
IAT sensor circuit shorted to
the ground.
1A-22

Hide quick links:

Advertisement

Table of Contents
loading