• Boost
The minimum current applied to the internal motor when starting the servo can be set. Since a small 
travel does not start the motor, it essentially feels like the dead band was expanded. The motor can be 
immediately started by adjusting the minimum current which can start the motor.
[Relationship between boost set value and servo operation]
Small   Motor reacts to a minute current and operation becomes smooth.
Large 
 Initial response improves and output torque increases. However, if the torque is too large, 
operation will become rough.
• Boost ON/OFF
OFF : It is the boost ON at the time of low-speed operation. (In the case of usual)
ON : It is always the boost ON. (When quick operation is hope)
• Damper
The characteristic when the servo is stopped can be set.
When smaller than the standard value, the characteristic becomes an overshoot characteristic. If the 
value is larger than the standard value, the brake is applied before the stop position.
Especially, when a large load is applied, overshoot, etc. are suppressed by inertia and hunting may 
occur, depending on the conditions. If hunting (phenomena which cause the servo to oscillate) occurs 
even though the Dead Band, Stretcher, Boost and other parameters are suitable, adjust this parameter 
to a value larger than the initial value.
[Relationship between damper set value and servo operation]
Small   When you want to overshoot. Set so that hunting does not occur.
Large 
 When you want to operate so that braking is not applied. However, it will feel like the servo 
response has worsened.
(Note) If used in the hunting state, not only will the current consumption increase, but the life of the 
servo will also be shortened.
• Stretcher
The servo hold characteristic can be set. The torque which attempts to return the servo to the target 
position when the current servo position has deviated from the target position can be adjusted.
This is used when stopping hunting, etc., but the holding characteristic changes as shown below.
[Relationship between stretcher and servo operation]
Small   Servo holding force becomes weaker.
Large   Servo holding force becomes stronger.
(Note) When this parameter is large, the current consumption increases.
• Buzzer
When the power supply of a servo is previously turned on at the time of a power supply injection 
without taking transmit of a transmitter, the buzzer sound of about 2.5 Hz continues sounding from a 
servo. 
(Even when the transmit of a transmitter is taken out previously, a buzzer sounds until the signal of a 
servo is outputted normally, but it is not unusual.) 
The transmitter has been turned OFF ahead of a servo power supply → The buzzer sound of about 1.25 
Hz continues sounding as servo power supply end failure alarm.
Do not insert or remove the servo connector while the receiver power is ON. A buzzer may 
(
sound by incorrect recognition.
*Buzzer sound is generated by vibrating the motor of a servo. 
Since current is consumed and a servo generates heat, please do not operate the number more than 
needed or do not continue sounding a buzzer for a long time. 