GOV. Expert(Governor Expert Setting)
GOV. Expert(Governor Expert Setting)
(6) Revo. Up Dly: Revolution change up delay
How quickly the RPM changes when increasing RPM between two differ-
ent  RPM  conditions  and  flight  modes.  A  higher  number  slows  the  RPM 
change rate; a lower value speeds up the RPM change rate.
Setting ranges:  2 ~ 40 Frm     Initial value: 8 Frm
(7) Revo. Dn Dly: Revolution change down delay
How quickly the RPM changes when reducing RPM between two differ-
ent  RPM  conditions  and  flight  modes.    A  higher  number  slows  the  RPM 
change rate; a lower value speeds up the RPM change rate.
Setting ranges:  2 ~ 40 Frm     Initial value: 10 Frm
(8) Start Dly: Start delay
How  quickly  the  RPM  stabilizes  to  the  set  RPM  from  when  the  GOV  is 
turned ON.  A higher value slows down the spool up rate; a lower value 
speeds up the spool up rate. 
Setting ranges:  2 ~ 20 Frm     Initial value: 5 Frm
(9) Gov. On. Revo: Governor ON revolution setting
This parameter tells the governor at what percentage of the set rpm it is 
to become active.  The default value is 60%. In this case, the governor will 
not engage until the engine rpm reaches 60% of the set rpm.  If you feel 
that the time for governor engagement is too slow, decrease the value to 
50 ~ 55%. The starting time will be faster.
Setting ranges:  50 ~ 90%     Initial value: 60%
(10) BFS. Volt: Battery F/S voltage setting
This  parameter  sets  the  battery  fail  safe  and  low  battery  alarm  voltage 
levels,  or  thresholds.    Set  the  proper  voltage  as  determined  by  the  bat-
tery  type.    The  battery  characteristics  are  different  depending  on  cell 
type/chemistry. 
Suggested setting voltages are as follows.
• 4 cells NiCd or NiMH (Normal: 4.8 v) = 3.8 v
• 2 cells LiFe (Normal: 6.6 v) = 6.0 ~ 6.2 v
• 2 cells LiPo (Normal: 7.4 v) = 7.2 ~ 7.4 v
(11) Low. Revo: Low revolution setting
This value is set to assign the lowest possible governing RPM.  If the RPM 
is below, or can not reach this RPM, the governor will not engage.  Select 
between either 1,000 rpm or 700 rpm.  It corresponds also to a helicopter 
with a rotor speed of 1,000 rpm or less, such as a large gas machine.
Setting:  700 / 1,000 rpm     Initial setting: 1000 rpm
(12) RESET : Governor expert data reset
This resets the "GOV. EXPERT" setting back to the defaults.