< Model Menu (Helicopter) >
204
Swash Basic
Swash Basic
(14) Pit. High: Pitch high memorizing
This parameter saves the full positive collective pitch point into the CGY.
[Setting method] Touch the "Pit. High" rate button to enter the setting
mode. "Sure?" Is displayed. Operate the throttle stick fully to the high. If
you touch the [Yes] button. The full positive pitch signal will be saved to
the CGY.
(15) Pit. Zero: Pitch zero memorizing
This parameter saves the zero collective pitch point into the CGY.
[Setting method] Touch the "Pit. Zero" rate button to enter the setting
mode. "Sure?" Is displayed. Operate the throttle stick to 0 degree pitch. If
you touch the [Yes] button. The zero pitch signal will be saved to the CGY.
(16) Pit. Low: Pitch low memorizing
This parameter saves the full negative collective pitch point into the
CGY. [Setting method] Touch the "Pit. Low" rate button to enter the
setting mode. "Sure?" Is displayed. Operate the throttle stick fully to the
low. If you touch the [Yes] button. The full negative pitch signal will be
saved to the CGY.